Download Inhoudsopgave Inhoud Print deze pagina

Installation Of The Supporting Feet - Dimplex DX421 Installatiehandleiding

Inhoudsopgave

Advertenties

ATTENTION!
Ensure there is a minimum of 230 mm below
the heater, 450 mm above the heater and
750mm in front of the heater of unobstructed
space.
ATTENTION!
In order to avoid a hazard due to inadvertent
resetting of the thermal cutout, this appliance
must not be supplied through an external
switching device, such as a timer or
connected to a circuit that is regularly
switched on and off by the utility.
ATTENTION!
DO NOT use the heater on deep pile carpets or
the long hair type of rugs. Keep combustible
materials such as drapes and other furnishings
clear from the front, sides and rear of the heater.
Do not use the heater to dry your laundry.
2
Technical data
Connection voltage: 1/N/PE~, 230 V, 50 Hz
Protection type:
IP20
Protection class:
I (with protective conductor)
Type
Heat out-
Width
put (W)
(mm)
DX 421
2000
575
DX 422T
2000
575
DX 431
3000
695
DX 432T
3000
695
DX 432Ti
3000
695
3
Installation
The heating device may only be installed as shown, i.e.
on a horizontal, even surface. Using it on deep-pile car-
pets is not permitted. Please use caution when install-
ing it in front of flammable objects. Installation below a
wall socket is not permissible. Minimum clearances
must be observed.
In addition, a minimum clearance of 750 mm between
flammable objects e.g. curtains, towels or heat-sensitive
plastics and the front of the unit must be maintained.
All manuals and user guides at all-guides.com
Height
Depth
Weight
(mm)
(mm)
(kg)
350
200
4,1
350
200
4,3
350
200
4,7
350
200
5,1
350
200
5,2
DX 421, DX 422T, DX 431, DX 432T, DX 432T

3.1 Installation of the supporting feet

Do not use the heating device
without the feet being fitted.
The two mounting screws for
the supporting feet (A) are lo-
cated on the bottom of the de-
vice. Loosen the mounting
screws.
Engage the supporting feet as
shown in the illustration and
tighten the screws.
4
Electrical Connection
The voltage specified on the type plate must match the
local mains voltage.
The device plug must always be accessible.
5
Operation
The room temperature is regulated using the adjusta-
ble thermostat (C). If the rotary knob is set to the lowest
setting i.e. to the extreme left (see figure), the thermo-
stat switches the heating device on at an ambient tem-
perature of approx. 5°C.
The heating device is switched on and off using the
power switch (D).
Two heating levels (I = Low or II = High) can be se-
lected using the operating mode switch (E).
The red light illuminates when the device is in heating
operation.
ATTENTION!
Depending on the size of the room, heat requirement
and thermostat setting, rooms may overheat if the
heating is not controlled. This can be dangerous for
people who are not able to leave the room as it gets too
hot.
F
EN-7

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Dx 422 tDx 431Dx 432 tDx 432 ti

Inhoudsopgave