Download Inhoudsopgave Inhoud Print deze pagina

Grounding; Mounting The Polishing Brushes; Electrical Components - Huvema HU 175 P Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

6.3 Grounding

The grounding is carried out by connecting the yellow/green terminal of the supply cable to the grounding
terminal of the power source. Be sure the ground the machine in any situation before connecting the machine
to the power source.
Warning
Do not disconnect the grounding terminal before disconnecting from the power source.

7. Mounting the polishing brushes

Check that the machine is "Off" and disconnect from the power source. Put the polishing brush on the shaft
(see Fig. 4).Check if it is firmly installed. Clamp the machine tightly on to a work bench or a stand. This will
increase safety.
8. Universal work stand
A work stand is additionally available. Refer to Figure 6 for the construction and assembly of the stand.
No. Description
1
Stand leg (front/rear)
2
Stand leg (left/right)
3
Stand top
5
5
4
Screw
/
-18NC x
16
5
5
Hex. bolt
/
-18NC x ¾"
16
5
6
Hex. bolt
/
-18NC x 1½" 2
16
5
23
7
°x
Washer
/
x
/
16
32
5
8
Spring washer
/
"
16
5
9
Hex. nut
/
"-18NC
16

9. Electrical components

See Figure 5 for the wiring diagram
Designation
KA
XP
10. Parts lists
See Figure 7
No.
Description
1
Screw
2
Spring washer
3
Left support
4
Ball bearing
5
Centrifugal switch
6
Screw
7
Stator housing
8
Stator
All manuals and user guides at all-guides.com
Qty.
2
2
1
/
"
4
8
16
1
24
/
"
16
22
22
Description
Magnetic contactor
Plug for supply
Cable
Specification
240 Vac, 6.0 A
250 V, 16 A
H05-VVF, 3 x 0.75 mm²
No.
Description
28
Rubber plate
29
Screw
30
Screw
31
Cover plate
32
Dustproof cover
33
Screw
34
Switch
35
Cover plate
-13-
Remark
VDE0620

Advertenties

Inhoudsopgave
loading

Inhoudsopgave