Create a space to install your hob , following the dimensions indicated on figure.
•
100 mm from edge of cooker to combustible materials.
•
7 0
0 mm underside of overhead cupboards, shelving
•
750mm underside of overhead exhaust fans.
This appliance must be installed according to the manufacturers installation
instructions, local building regulations, gas authority codes and electrical wiring
instructions.
Changing the Gas Inlet
The gas feeding manifold protruding from the back of the hob must be visible
completely, any means connection (nut,hose etc.)must be placed with attention to
avoid any contact with parts that will heat up. It is highly recommended to block the
access to pipe connection, while the
During the gas connection process, the pipe of the appliance should be kept
stationary, while the connected part (mechanical, LPG or NG nut) is fixed.Always
use the seals supplied in the spare set between the connection 'A' for flexible hose
connection.
For connection of methane type gases (NG),
•
Use B type connection in Spain, Italy, Portugal, Greece, France and Algeria for
o
use with flexible hose conection.
•
Use C type connection in Letonia and Luxemburg for mechanical connection.
o
This connection may also be optionally used in some areas in France, Algeria,
o
Spain, Portugal and Italy.
•
Use C type connection in Germany and Belgium with an additional
o
ISO7/ISO228 adapter and Netherlands with an additional Besca adapter,
o
supplied in the spare set. An example of usage is shown in E.
All manuals and user guides at all-guides.com
hob
is in use or when the gas supply is open.
.
:
5