GAS CONVERSIONS
Transformation For The Gas Cookers Replacement Of Injectors
GAS CONNECTION
The installation of the gas appliance to natural gas or LPG
must be carried out by a gas safe registered engineer.
Engineers shall take due account of the provisions of the
relevant British Standards Code of practice, the gas safety
regulations and the building standards (Scotland)
(Consolidation) regulations issued by the Scottish
development department.
The gas burners adapt to different types of gas, by replacing
the corresponding injectors to gas on use.
There fore it is necassery to;
• Cut off the feeding gas flow and electric current.
• Remove the cap and the adapter.
• Unscrew the injectors.
• Replace the injector with the ones corresponding to the type of gas that is
o
going to be used, according to the information on the transformation chart.
INJECTORS REPLACEMENT OF HOB BURNERS
I
This appliance is manufactured for conversion to LPG. To purchase an LPG
conversion kit, contact the store where you purchased this appliance. The
diameter is marked on the injector in cents of millimetre.
Select the injectors to be replaced according to the "Table for the choice of the
injectors". To replace the injectors: Remove pan-supports and burners from the
hob top. sing a spanner, remove the injector from its housing and replace it by
U
the proper one according to the kind of gas (see
injectors").
Adjusting The Reduced Flame Position
For reduced flame position the by pass screw must be loosened in
transformation from LPG to NG. In transformation from NG to LPG, the same
screw must be
tightened.
• Make sure that the appliance is unpluged from the electric current and the gas
o
feed is open.
• Ignite the burners and leave them on in minimum position.
• Remove the knobs and rubber seals because the screws are accesible only
o
when the knobs and the seals are removed.
• This procedure must be
12
All manuals and user guides at all-guides.com
repeated
for each of the valves.
the
"Table for the choice of the