14
Technical Information
EN
S/N
• S / N (Serial Number) Description
Machine ID
X
X
X
X
Machine
Model
Group
Order
Temperature (C°)
Duty Cycle
As defined in the standard EN 60974-1, the duty cycle rate includes a time period of 10 minutes.
6 min.
For example, if a machine specified as 250A at %60 is to be operated at 250A, the machine can weld / cut
without interruption in the first 6 minutes of the 10 minutes period (zone 1). However, the following
4 minutes should be kept idle for the machine cool down (zone 2).
1.4 Technical Data
Mains Voltage (3-Phase 50-60 Hz)
TECHNICAL DATA
Power Source Efficiency
IDLE State Power Consumption
Welding Current Range
Rated Welding Current
Open Circuit Voltage
Dimensions (l x w x h)
Protection Class
USER MANUAL
Three Phase Transformer Rectifier
Horizontal Characteristic
MIG/MAG Welding
Direct Current
Mains Input 3-Phase Alternating
Current
Suitable for Operation at Hazardous
Environments
Serial Number
Production
Sequence Number
Year
Week
X
X
X
X
X
X
Sequence number of
the machine produced
within that year
4 min.
6 min.
Rated Power
Weight
X
U0
U1
U2
I1
I2
S1
IP 23
X
X
X
4 min.
V
UNIT
kVA
%
W
ADC
ADC
VDC
mm
M
M
MW
kg
MW
M
MW
Duty Cycle
Open Circuit Voltage
Mains Voltage and Frequency
Rated Welding Voltage
Rated Mains Current
Rated Welding Current
Rated Power
Protection Class
6 min.
4 min.
400
ID 350 M-MW ECO
18.9 (%40)
85,21
23
50 - 350
350
62
1137 x 528 x 1161 mm
1170 x 528 x 1430 mm
96
120
IP 23
www.magmaweld.com
ECO SERIES
Time (min.)