Risk of fatal injury from electric shock!
Touching live electrical parts may result in electric shock�
• The bathroom extractor fan is designed for permanent indoor connection,
for fixed electrical installation, which must be equipped with means/devices
for total contact breakage in order to ensure complete separation under
overvoltage conditions of category III according to the regulations for such
installation�
• The bathroom extractor fan is designed for installation at a substantial
height, i�e� 2,3 m above the floor� Installation - only in accordance with the
descriptions and guidelines in this manual, in particular with regard to the
required installation position, by inserting the power cord into the housing�
• Measures shall be taken to prevent gases from escaping from open smoke duct or other open flame
equipment into the room�
• Unauthorised changes or modifications to the equipment are not permitted�
• Before installing the equipment, check the load-bearing capacity of the structure to which it is to be
mounted, as improper mounting can lead to damage or destruction of the equipment and can pose
a risk to persons in the vicinity of the equipment in the following situations�
The appliance may become dangerous
if used improperly or if installed by unqualified personnel.
3 APPLICATION AND OPERATING CONDITIONS
• Bathroom extractor fans are designed to transport normal or slightly dusty air (particle size <10 μm)
of low aggressiveness and humidity in temperate climates according to and within their limits
of performance�
• The appliance is designed only for continuous operation in a building if there is no access
to the power supply line�
• The maximum temperature of the medium handled by the bathroom extractor fan and the maximum
ambient temperature are +40°C�
• The exhaust fan is IP4 and protection class II device if it is installed in accordance with Appendix
1 (Fig� 5) in the wall� The fan is not designed for ceiling installation�
• The bathroom extractor fan must be operated according to its intended use and in accordance
with the data provided on the rating plate�
• The bathroom extractor fan must be connected to the building mains (recessed electrical installation)
with one of the following power cable: NYM-O 2x1,5 mm
depending on the fan version - see point 6� If a cable with more wires has to be used,
e�g� NYM-J 4x1,5mm
• The bathroom extractor fan cannot be used to circulate air with the following characteristics:
- viscous contaminants prone to deposition in the bathroom extractor fan,
- corrosive contaminants which may degrade the bathroom extractor fan,
Fan 1500, Fan 1500 DH
, the outer diameter of the cable must not exceed 14mm�
2
; NYM-O 3x1,5 mm
; NYM-J 3x1,5 mm
2
2
,
2