 Incorrect dimension of the air duct.
 Obstruction in the air duct.
 The diameter of the air duct from hood to wall-box inclusive should be 120
mm; otherwise the capacity of the motor may be decreased.
 If you have installed a fly screen on the wall-box, the air vent may be
obstructed. Check by removing the fly screen.
 If the cover panel of the wall box is equipped with firm and slanted slats, the air
vent may be obstructed. Check by removing the cover panel.
 Install a cover panel with moveable slats, which do not obstruct the air vent.
 Check condition and cleanliness of the filters.
 Check if the air which is extracted by the hood is replaced to avoid negative
pressure.
 When you run your appliance in recirculating mode, check if the carbon filter
has been replaced on time (min. every 3-6 months).
If the appliance has a malfunction not noted on the schedule or if you have
checked all items on the schedule but the problem still exists, please contact the
shop you purchased the appliance at.