ELECTRICAL CONNECTION
Attention: this hob includes a power cord with a Perilex plug. The connection is a 2 fase-connection.
• Check that the voltage in your home corresponds with the voltage printed on the bottom of the appliance.
• The earthing of the appliance is compulsory by law.
• Attention: the connection point must always be accessible.
IMPORTANT: the hob is connected according to the schedule 2L-2N, 230V ac.
If a different connection is needed, the appliance should only be connected by a qualified fitter. Improper connection can cause the
hotplates to burn out. This is not covered by the guarantee.
Connection from factory 2L-2N 230V~
L-N 230V~
2 ~ -1N 230V~
16
•
English
VKE6010-instructions.indd 16