All manuals and user guides at all-guides.com
Example:
<STX><FF>LE300DB10090541169D00442<EOT>
300DB10090 = Transponder number
5411 = 11:54 AM
69 = 01 10 1001 = 01 access currently refused, 10 1001 = 2 9 for 29th day
D0 = 110 1 0000 = 110 transponder held in the field; 1 0000 = 10 = October
04 = year 04
42 = CRC
Command: Serial number (S)
Command description: This command is used to set and read the serial number.
Caution:
The 1st byte of the serial number is the address of the transponder reader. The
„INDEX" is always 0000.
Format:
<STX><ADR>LP<INDEX><CRC><EOT>
<STX><ADR>SP<INDEX><DATA><CRC><EOT>
Data format: The serial number is indicated with 20 digits (10 Byte).
Example:
<STX>FFLS0000EB<EOT>
<STX>FFLSFF12345678901234567868<EOT>
Reads the serial number FF123456789012345678 from the transponder reader. I.e. the
address of the transponder reader is FF (first byte).
68