9. Commissioning
For configuration, connect the RS232 connection of the control module to an RS232-
interface of a PC.
Switch on the operating voltage.
The product is then ready for operation.
Before the relay in the control module can switch, you first need to teach in at
least one transponder and set a user, and possibly a time scheme (when the
transponder can activate the relay).
RS232 Settings
The communication with the control module takes place via the standard-RS232-protocol.
The following connection settings must be observed:
Baud Rate: 57600
Data bits:
8
Stop bits:
1
Parity:
none