4. Configuration
CF06 - ON/OFF button display in standby mode
0
Symbol
not displayed in standby mode
1
Symbol
displayed in standby mode
CF07 - Backlighting
0
1
Enabled (switches off after timer)
CF08 - Opening detection function
0
1
If a door/window magnetic contact (e.g. window) is associated with
the receiver, the heating will switch to Frost protection when the
window is opened.
Disabled
Disabled
Enabled
- 38 -
- 38 -
CF09 - Presence detection function
0
1
If a motion detector is associated with the receiver, the
temperature will be lowered automatically in the event of an
extended absence:
• 1.5 h -> Active setting -1.5°C
• 3.5 h -> Active setting -3.5°C
• 48 h -> Frost protection setting
CF10 - Value of the max. comfort setting
Can be set from 22°C to 30°C.
Default value: 28°C
CF11 - Programming format
Programming in 1 h steps
0
1
Programming in 1/2 h steps
Disabled
Enabled
- 39 -
- 39 -
EN