4. Configuration
1
>5s
The thermostat must be in shutdown mode.
❶ Press and hold the 2nd button from the left for 5 seconds.
The screen displays the thermostat version.
❷ Press OK.
The screen displays the CF01 menu.
❸ Choose your selection or setting with + and -.
Press OK to validate and go to the next setting.
To exit the mode, turn the selector knob
Note: the greyed out sections of the tables match the default
values
CF01 - Correcting the temperature measured
Can be set from -5°C to +5°C.
Example: the temperature displayed by the unit is 19°C and the
actual temperature (thermometer) is 20°C, set +1°C.
2
- 5°C -> + 5°C
3
- 36 -
- 36 -
4
CF02 - Temperature displayed in AUTO mode
0
1
CF04 - Control type
0
1
CF05 - Energy saving mode
Display switches off after 10 seconds if nothing is pressed
0
1
Display switches off between midnight and 5am
2
EXIT
Temperature setting
Temperature measured
Chrono-proportional
(PI) control
ON/OFF control
Display always on
- 37 -
- 37 -
EN