36
Installation
The following instructions about ins-
tallation and maintenance must be
carried out by qualified personnel in
compliance with the regulation in
force. The regulation to be applied for
this type of installation is NBN D
5I.003 : "Installations functioning
with combustible gas lighter than
air".
The side walls of the unit in which the
hob is going to be installed, must not
exceed the height of the working top.
Avoid installing the appliance in the
proximity of inflammable materials
(e.g. curtains, tea towels etc.).
The appliance must be electrically
disconnected before all interventions.
If any electric supply to the appliance
is required to carry out the work,
ensure all the necessary precautions
are followed.
Gas Connection
It is indispensible that the connection to
the gas mains are carried out by means of
an AGB tap. Choose fixed connections or
use a flexible pipe in AGB (stainless steel).
If using flexible metallic pipes, be
careful they do not come in contact with
mobile parts or they are not squeezed. Use
the same attention when the hob is
combinated with an oven.
This hob can be operated by Slochteren
gas (G25) with a nominal pressure of 25
mbar or by natural gas with nominal pres-
sure of 20 mbar. No regulation is required
for use by these two types of gas. Before
fitting the appliance ensure that the instal-
lation has the correct voltage for the
appliance. At full capacity, the drop in pres-
sure must not exceed 5%. Such a drop in
pressure is caused by the following
parameters: