Install the exhaust duct
The motor outlet has a diameter of 150 mm. It is recommended to connect an exhaust duct with a diameter of 150 mm
to this.
For optimum performance of the hood it is important to pay attention to the points given below.
Circular ducts:
• Use smooth, non-flammable pipes with an internal diameter that is equal to the external diameter of the connection
nozzle of the hood. Maximally extend flexible ducts and cut them to size.
• Do not reduce the exhaust diameter. This will lower the capacity and raise the noise level.
• When connecting to a short exhaust duct, it may be required to mount a non-return valve in the duct to avoid wind
blowing in.
• Use a hose clamp or aluminum tape for airtight connections.
• In case of an exhaust pipe through the wall, use a wall vent.
Flat duct:
• Use flat duct with rounded corners and with air deflectors. Available at Novy.
General information:
• Make the duct as short as possible and with as few as possible bends to the outside.
• Avoid square bends. Use rounded bends for proper air conduction.
• In case of an exhaust pipe through the outside wall passing a cavity wall, make sure that the exhaust duct fully bridges
the cavity and slightly declines to the outside.
• In case of an exhaust pipe through the roof, use a double-walled roof passage with sufficient width.
• Never connect to a flue duct.
Make sure that sufficient air is supplied. Fresh air can be supplied by slightly opening a window or an outside

ACCESSORIES

Recirculation
In case of recirculation Novy provides charcoal filters.
Various accessories
Clamp Ø60-215 mm
Aluminium tape (per 50 m)
Aluminium wall vent for outlet Ø150mm
One-way valve Ø150mm
Stainless steel cleaner
All manuals and user guides at all-guides.com
906291
906292
906178
906432
906060
EN 11