General
These are the mounting instructions for the Novy hood shown on the cover. The manual is a separate booklet that
has been supplied with this hood. Read these instructions carefully before installing and commissioning the hood. It is
recommended to have one or more qualified persons carry out the installation.
Carefully take the hood from the packaging. Check if all mounting materials have been supplied using the drawings on
page 2.
The hood is to be used above a hob and/or domino and intended for household use only.
Important before mounting
Page 2 of these mounting instructions show the mounting drawings. Observe the following mounting tips before starting
the mounting activities:
•
For easier mounting of the telescopic hood it is recommended to do this with at least 2 persons.
•
Check if all mounting materials have been supplied using the drawings on page 2.
•
Position the wall socket such that it is near the hood.
•
Make sure that the wall has sufficient load bearing capacity.
Exhaust or recirculation
Before starting any mounting activities, you must have made the choice if you are going to make an exhaust duct to the
outside or if you are going to use the hood as a recirculation hood. In case of an exhaust duct to the outside, carefully
read the section in these mounting instructions for installing the exhaust duct. For recirculation, please separately order
the recirculation kit.
INSTALLATION
Follow the mounting drawings on page 2.
Check the mounting materials against drawing 1.
1
Determine the mounting height 'h' above the hob:
2
• Recommended mounting height with electric or ceramic hob (Hmin-Hmax) (mm): 600 - 750
• Mounting height with gas or induction hob (Hmin-Hmax) (mm): 650-750
Draw the vertical axis A of the chimney hood on the wall. The level line B is drawn at the chosen height of 'h' + 480
3
mm. Position the socket outlet near the vertical axis A within the width of the shafts and preferably as close to the
ceiling as possible.
4
The drilling jig is included separately with these mounting instructions. Place this drilling jig on the crossing point of the
axis A and the level line B and draw the 2 holes on the level line. Drill holes in the wall using an 8 mm drill.
Mount the mounting brackets to the level line B.
5
The suspension can be levelled by turning the adjustment screws (below). This can be done beforehand, or after the
6
extraction hood has been removed from the wall.
Mount the upper spacer bracket at 20mm between the ceiling and the centre point of the holes in the bracket. Make
7
sure that the spacer bracket is mounted perpendicular to and in the centre of the vertical axis. Use the plugs and the
screws.
Hang the extraction hood over the mounting brackets.
8
There are 2 holes at the top of the chimney hood. Mark these holes on the wall. Remove the wall-mounted chimney
9
hood from the wall in order to drill the marked holes. Drill the holes with a 8mm drill and use the plugs. Position the
chimney hood against the wall again. Check if the hood is still hanging level. Use the screws to properly attach the
wall-mounted chimney hood to the wall.
10
Place the exhaust pipe on a connection nozzle of the motor using aluminium tape or a hose clamp. Put the plug into
the wall socket.
Take the two shaft parts and place them onto the wall-mounted chimney hood. Make sure that this is done carefully
11
in order to prevent the chimney hood or the shafts from being damaged. Screw the upper shaft tight to the spacer
bracket with 2 screws.