MONITOR SETTINGS
CODE configuration switch:
Dip1: Must be in O . N
Dip2 to Dip8: To configure the desired cod (2= most significant bit and 8= least significant bit). Below is an
example of a site with 22 apartments:
EL632/GTWIN
( )
Factory default.
*
Monitor ode
C
Monitor Code
ON
ON
( )
*
C.126
C. 00
1
2 3
4 5 6 7 8
1
2 3
ON
ON
C. 10
C. 09
1
2 3
4 5 6 7 8
1
2 3
ON
ON
C. 08
C. 07
1
2 3
4 5 6 7 8
1
2 3
EL60 D
6
ON
ON
C. 06
C. 05
1
2 3
4 5 6 7 8
1
2 3
ON
ON
C. 04
C. 03
1
2 3
4 5 6 7 8
1
2 3
ON
ON
C. 02
C. 01
1
2 3
4 5 6 7 8
1
2 3
INT configuration switch:
Define the internal code of the monitor in order to set it as master, slave 1, slave 2 or slave 3 using the INT
switch with a code from 0 to 3 respectively.
IMPORTANT: For optional connections and more information, see the "T
WIRING DIAGRAM
One building with 1 column of up to 127
monitors
(max. 24 ART 5W Gtwin with WiFi activated) and 1 main video panel (buttons).
ON
OFF
J3
E. Line
O N
O N
ON (Z)
=
=
ON
OFF
J3
E. Line
O N
O N
ON (Z)
=
=
Important: Max. 24 "ART 5W/GTWIN"
monitors with WiFi activated and the
RAP-GTWIN cable (Golmar).
J3
( )
Remove the jumper from all of the
*
E. Line
distributors except the last.
ON (Z)
1 ( )
To configure the SAV-GTWIN call repeater,
see the "TART 5W GTWIN " manual.
J3
( )
2
To connect the FA-Gtwin power supply to
E. Line
the filter and line protector, see the
ON (Z)
"TGTWIN SYSTEM MANUAL", p.44.
( )
3
To connect the secondary AC lock release
(Golmar), see the TGTWIN SYSTEM
"
Video door
entry system
MANUAL ", page 45.
Remember: Button panel up to 122 apartments.
Important:
-For further information about the door panel,
sections,distances,wiring diagrams, etc., see
the TGTWIN SYSTEM MANUAL, code
50122345).
https://doc.golmar.es/search/manual/50122345
Monitor Code
Monitor Code
EL610D
ON
C. 20
C. 19
4 5 6 7 8
1
2 3
4 5 6 7 8
ON
C. 18
C. 17
4 5 6 7 8
1
2 3
4 5 6 7 8
ON
C. 16
C. 15
4 5 6 7 8
1
2 3
4 5 6 7 8
ON
C. 14
C. 13
1
2 3
4 5 6 7 8
4 5 6 7 8
ON
C. 12
C. 1
1
1
2 3
4 5 6 7 8
4 5 6 7 8
4 5 6 7 8
Factory default.
( )
*
( )
*
ART 5W
GTWIN" manual.
COLUMN
DISTRIB I OR
U T
LINE OUT
D4L-GTWIN
MASTER
MONITOR
LINE
LINE
BUS IN
BUS IN
INT
3
4
ON
BUS OUT
Apartment
Apartment
BUS OUT
( )
Z=ON
*
HZ
Front
Front
HZ
1
2
door call
door call
GND
INT 0
GND
SA
SA
MASTER
MONITOR
LINE
LINE
BUS IN
BUS IN
INT
1
2
Apartment
ON
BUS OUT
Apartment
BUS OUT
LINE IN
HZ
Front
Front
HZ
1
2
door call
door call
GND
INT 0
SA
GND
SA
TO NEXT DISTRIBUTORS
DISTRIBU O
T R
D4L-GTWIN
LINE OUT
MASTER
MONITOR
LINE
LINE
BUS IN
BUS IN
INT
3
4
ON
Apartment
Apartment
BUS OUT
BUS OUT
Z=OFF
Front
HZ
Front
HZ
1
2
door call
door call
INT 0
GND
GND
SA
SA
MASTER
MONITOR
LINE
LINE
BUS IN
BUS IN
INT
1
2
ON
BUS OUT
Apartment
BUS OUT
LINE IN
Apartment
HZ
Front
Front
HZ
1
2
door call
GND
door call
INT 0
GND
SA
-S
SA
Main p
anel
+S
1 ( )
SAV-GTWIN
callrepeater
LINE
PA
Exterior door release
button
SP
NC Contact=
SE+
( )
SE2
3
Door closed
SE-
NOTE: If not use, join
Lock release
connection terminals 'SP'
m x. 12 V c/270mA.
a
d
with a wire.
4
( )
*
CODE
INT
1 2 3 4 5 6 7 8
1 2
ART 5W/GTWIN MONITOR
ON
1
2 3
4 5 6 7 8
ON
1
2 3
4 5 6 7 8
ON
1
2 3
4 5 6 7 8
ON
1
2 3
4 5 6 7 8
ON
1
2 3
4 5 6 7 8
ON
ON
ON
ON
1
2
1
2
1
2
1
2
INT 0
INT 1
INT 2
INT 3
DS551205-002B
J3
M
ASTE
R
E. Line
MONITOR
ON (Z)
INT
ON
1
2
INT 0
J3
MASTER
E. Line
MONITOR
ON (Z)
INT
ON
1
2
INT 0
J3
MASTER
E. Line
MONITOR
ON (Z)
INT
ON
1
2
INT 0
J3
MASTER
E. Line
MONITOR
ON (Z)
INT
ON
1
2
INT 0
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
FA-GTWIN
POWER SUPPLY
Golmar reserves the right to make any modifications without prior notice.
LINE 1
LINE 2
230
L N ~
I E
0
( )
2
EN
QUICK GUIDE
Golmar se réserve le droit de toute modification sans préavis .
TART 5W GTWIN E GR REV.0
golmar@golmar.es
www.golmar.es
Sistemas de comunicación S.A.
LBT21118
N
123
EN