Fault table 16A
Warning: The unit should be de-energised immediately in the event of a malfunction. Repairs
should only be entrusted to trained and qualified skilled personnel.
Malfunctions
The compressor motor
does not start
Compressor running,
but does not build up pressure
Compressor deactivates
during operation
Compressor running,
but work is not realised
Compressor does not start
by if pressure is
below minimum
or does not deactivate
at max. pressure
Compressor becomes too hot
Note: No claim is made to the completeness of the possible malfunctions listed here.
16 ENGLISH
Possible causes
No power
Cable breakage or loose
electrical connections
Pressure in tank too high,
pressure switch triggered
Covering cap has not been
removed from the suction pipe
Motor is too hot, motor circuit
breaker triggered
Unit is leaking
Pressure switch defective
Room temperature too high
or air supply is
inadequate
Compressor excessively
overloaded
Remedy
Check fuse and plug
Specialist workshop
Release air from tank
Remove covering cap
Deactivating compressor, allow
motor to cool
Check hose and snap
connections for leaks
Have pressure switch replaced
specialist workshop
Ensure that air supply is
adequate
Check whether compressor is
suitable for load
Ausgabe 07.1