maintenance
cleaning
carbon filter
If you plan to use the appliance as a recirculation hood, you
must first install the carbon filter. You must then also set the
switch located at the back of the appliance to F. In the case
of normal use the carbon filter must be replaced twice
annually. In the case of intensive use the carbon filter should
be replaced more frequently.
installing / replacing
1
Remove the grease filters.
2
Remove the cover from the carbon filter housing.
A
3
Place the carbon filter in the carbon filter housing.
4
Secure the filter with locking pin A.
5
Reinstall the carbon filter cover.
6
If necessary set the switch in the appliance to position "F"
(filter mode) (see also "setting", below).
7
Reinstall the grease filters.
setting
Remove the filters from the extractor hood.
If you are going to use the appliance as a recirculation hood,
A
set the switch located inside the appliance at the back to
position F (filter mode) (the flap is closed). You must then
also install the carbon filter (see "carbon filter", above).
F
If you are connecting the hood to a flue, set the switch
located inside the appliance at the back to position A (the flap
is open).
GB 10
All manuals and user guides at all-guides.com
faults
what should I do if...
If the appliance does not work properly, this does not always mean that it is defective.
Try to deal with the problem yourself first. Phone the service department if the advice
given below does not work.
attention:
Disconnect the appliance from the mains before starting the repair, preferably by
removing the plug from the socket or setting the main switch to zero.
fault
Lighting is not functioning.
Extractor hood makes a
noise.
No extraction.
cause
solution
Light bulb defective.
Remove the grease filters.
This gives access to the
light bulbs. Unscrew the
bulb from the fitting and
replace it with a new 40 W
bulb.
Halogen bulb defective.
Pull the inner ring
downwards with a
attention:
screwdriver (see
Use only the same light
illustration).
bulbs with the wattage
Take care: The glass is
stated.
loose!
Pull the halogen bulb out
of the fitting and replace it
with a new 20 W halogen
bulb. Use a clean cloth to
hold the new bulb.
Discharge too long or too
Change the discharge
many bends in the duct.
ducting (see installation
guide).
Motor defective.
Phone the service
department.
Motor or controls defective.
Phone the service
department.
Connection cable defective.
Phone the service
department.