The parameters have the following meaning:
Interval On
Defi nes the value Interval oN determines how long the relay T1 or the
connected fan is switched on for a limited time.
Setting range:
Factory setting:
Interval OFF
Defi nes the value Interval OFF determines how long the relay T1 or the
connected fan is switched on for a limited time.
Setting range:
Factory setting:
T1 (min)
The value for the indoor temperature defi nes the minimum acceptable tempera-
ture. The control is switched off when the internal temperature has reached this
value. An undesirable cooling of the room is prevented.
Setting range:
Factory setting:
T1 (max)
Defi nes the value for the indoor temperature defi nes the maximum acceptable
temperature. The control is switched off when the internal temperature has
exceeded this value. An heating of the room is prevented. This can e.g. be
interesting for a vegetable storage or a wine cellar.
Setting range:
Factory setting:
F1 (min)
Defi nes the minimum allowed value for the relative internal humidity. The
control is switched off when the internal humidity has fallen below this value.
This can prevent unwanted dehydration.
Setting range:
Factory setting:
64 |
64 |
62 |
Modes/ programs/functions
5...20 min
10 min
20...120 min
30 min
-40 °C...+120 °C
10 °C
-40 °C...+120 °C
30 °C
0,0 % RH...100 % RH
20 % RH