7-1. Fuse

Unscrew two screws of burner cover and re-
1
move the burner cover.
Unscrew the screw cap of fuse holder and
2
take out the fuse.
Unscrew two screws and take the
burner cover off

7-2. Nozzle

• Place the burner assembly taken out within the reach of two fuel hoses.
Remove three nuts from burner attachment
1
bolts and take the burner assembly off.
Unscrew three nuts and take the
burner unit off
Replace with a new one.
3
Put the screw cap back into fuse holder.
4
Put the burner cover back with two screws
5
removed.
EPX1
Fuse
Observations
Remove the nozzle using the nozzle wrench
2
provided as standard parts.
Replace with a new nozzle.
Loosen
Tighten the nozzle using the nozzle wrench
3
until the nozzle is fi xed.
Put the burner assembly back with three
4
nuts removed.
EPX5
Open a screw cap
and take out a
fuse.
Fuse
Check whether the
fuse is blown out.
18