• Normal = regular fixed FAN speed (FAN speed is selectable: low – medium – high)
• Natural wind = varying FAN speeds, giving a natural wind breeze with some high-speed
breezes.
• Sleeping wind = varying gentle FAN speeds, giving a natural wind breeze (on/off).
While pressing, a beep sounds and the selected airflow LED indicator lights up.
Oscillation
To control the vertical (left/right) direction of the airflow, press the OSC button on the device
or remote control
5
Timer setting
The timer can be set from 0 to 7 hours.
Press the TIMER button on the device
setting.
Each press adds 0.5 hour to the timer setting and the corresponding LEDs light up.
The timer sequence: 0.5 – 1 – 1.5 - 2 – 2.5 – 3 – 3.5 – 4 – 4.5 – 5 – 5.5 – 6 – 6.5 – 7 – 7.5
– OFF
Cancelling the set timer
Press the TIMER button on the device
switched off.
4) CLEANING AND MAINTENANCE
Warning
Before cleaning the device, always switch it OFF, disconnect it from the mains electricity
supply.
The device CANNOT be immersed in water.
Cleaning the device
• Never use aggressive or abrasive cleaning materials, cleaning alcohol or sharp objects
like hard brushes or knives.
• Clean the exterior of the casing with a damp cloth.
• Then dry the exterior with a dry cloth.
5) SPECIFICATIONS
• Voltage input: 220 - 240 Vac – 50/60 Hz
• Power consumption: 50W
• Class: II
• FAN speed: 3 modes
• Air velocity: 4 m/s
• Oscillation degree: 70°
• Sound level: ≤ 52 dB(A)
• Dimensions: 75 x 22 x 22 cm (H x D x W)
• Weight: 1.95 Kg