Item
Parameters
4
Time setting of
automatic re-
start running
after warning
shutdown (dry
running or
over pressure)
(α value)
5
Restore to
default value
setting
6
LCD screen
display
''loAd'' or
''- - - -'' for
3 seconds
to store
and finish
the setting
kinpumps.com
Display
Default
Data
Code
Unit
range
Auto
sec
1 - 600
reset
dF-n
-
-
dF-y
- - - -
-
-
or
loAd
Description
A. Select to modify automatic re-start time, press the left or right button to
adjust the value, after finish the setting, press the SET button, and go to
next parameter setting. The time of automatic re-start = (automatic time
setting) * (trip times)³
(Cumulative trip times is up to 10 times, if you press the right button to re-
start, then the trip times can be re-calculated.)
B. Stay on this screen for 30 seconds, the display screen will back to the
actual pressure conditions automatically and the preset data value is not
stored.
C. Choose not to modify the automatic re-start time, press the SET button,
and go to next parameter setting.
A. Select to restore default value settings (dF-y), press the right button and
adjust the parameter value from dF-n to dF-y. After finishing the setting,
press the SET button, then all the advanced value settings are returned to
default value. LCD screen display ''- - - - '' for 3 seconds and back to the
actual pressure conditions.
B. Stay on this screen for 30 seconds, the display screen will back to the
actual pressure conditions automatically and the present data value is not
stored.
C. Choose not to return to default value settings (dF-n), select dF-n and
press the SET button again, LCD screen display ''loAd'' for 3 seconds and
will back to the actual pressure conditions automatically.
After LCD screen display ''loAd'' or ''- - - - '' for 3 seconds later,
above setting value are stored and go to the actual pressure value
automatically.
CSP- 10 Control