7. Parameter display and settings

"
" (Pressure value display)
Item
Parameter
1
Max. pressure
setting
display
2
Min. pressure
setting
display
3
Pressure of
water
shortage
setting
display
(dry
running)
"
" (Restart or stop the pump running)
Item
Parameter
1
Restart
(ON)
2
Stop (OFF)
"
" ( Short press once to enter basic setting mode )
Setting procedure: Max. pressure → Min. start pressure → Time delay
Item
Parameters Display
1
Max. pressure
setting
(high pressure)
2
Min.
start pressure
setting
(low pressure )
kinpumps.com
Display
Default unit
Code
P-max
Kg/cm²
P-min
Kg/cm²
P-dry
Kg/cm²
Pump
Light
action
Pump
Orange
Press once to restart the pump running.
on
Pump
Non
Long press for 3 seconds to stop the pump
off
running.
Default
Data
Code
Unit
Range
P-max
Kg/cm²
0.01 –
10.00
P-min
Kg/cm²
0.01 –
10.00
Description
Press once: to see the max. pressure
se tting value
or stay on this screen for 5 seconds it will
re turn to the actual pre ssure status
display automatically.
Press again: to see the min. pressure
setting value
Or stay on this screen for 5 seconds it will
return to the actual pressure status
display automatically.
Press again. To see the pressure of the
water shortage setting value.
Or stay on this screen for 5 seconds it will
return to the actual pressure status display
automatically.
Description
a. Select to modify Max. Pressure, press the left or right button to
adjust the value, after finishing the setting, press the SET
button once and go to Min. start pressure.
b. Stay on this screen for 30 seconds, the display screen will back
to the actual pressure conditions automatically and the preset
data value is not stored.
c. Choose not to modify the pressure, press the SET button, and
go to the next parameter setting.
a. Select to modify min. start pressure, press the left or right button
to adjust the value, after finishing the setting, press the SET button
once and go to Time-Delay setting.
b. Stay on this screen for 30 seconds, the display screen will back to
the actual pressure conditions automatically and the present data
value is not stored.
c. Choose not to modify the pressure, press the SET button, and go
to the next parameter setting.
CSP- 10 Control
Description