Download Print deze pagina

Chamberlain RA5 Instructies pagina 13

Advertenties

Beschikbare talen

Beschikbare talen

Correct use
The RA5 - RA55 tubular drives are designed for the exclusive purpose of operating shutters and sun-blind systems. They serve to open
and close these systems and replace the person that is usually operating the installation. Therefore, tubular drives may only be installed
in faultless shutter- or sun-blind systems. Rough-running systems have to be repaired. Replace defective parts. This guarantees safe
operation and avoids damage during opening or closing.
Any other form of usage is deemed to be incorrect. Neither the manufacturer nor the supplier assumes any liability for personal injury, damage to
property or consequential injury or damage occurring as a result of the use of the control units and / or drives for purposes other than those
mentioned above or due to changes made to the equipment affecting the safety of the given system. The details stipulated in the Operating
Instructions in respect of the operation and repair of the system require strict observance. Neither the manufacturer nor the supplier assumes
any liability for personal injury, damage to property or consequential injury or damage occurring as a result of non-compliant actions.
In compliance with standard EN 60 335-2-97:2000, the cable connecting the drives to the mains cable must be laid internally.
According to DIN 18073 shuter box lid must always be easily accessible and removable.
Performance features
Model
Diameter
Torque
(mm)
(Nm)
RA5
35
6
RA15
45
10
RA35
45
25
RA45
45
30
RA55
45
40
Max. area (area = length x breadth)
RA5
PVC
3.5m
2
ALU
2.8m
2
WOOD
1.2m
2
AWNING
4.0m
2
INSTALLATION
Rough- in or install conduit pipe to the connector box for the electrical connecting line according to local building and electrical codes.
THE DRIVE IS PREMOUNTED. THE DESCRIPTION IS FOR CHECKING PURPOSES!
A
Carton Contents
1.
Motor (1)
2.
• Adjuster pin (2)
• Drive adapter safety catch (3)
• Square pin (RA5) (4)
• Square pin (RA15 - RA55) (5)
• Shaft adapter (6)
• Wall bracket (7)
3.
Manual
Fully unroll the shutter (a). Remove the shutter material from
B
the tube (b). Remove the manual control (c).
b
Speed
Operating
Voltage
(rpm)
(V)
14
230
15
230
15
230
15
230
15
230
RA15
RA35
5.0m
2
10m
2
4.0m
2
8.0m
2
2.0m
2
4.2m
2
6.0m
2
11.5m
2
c
a
Frequency
Current
input
(Hz)
(A)
50
0,43
50
0,49
50
0,83
50
0,83
50
0,86
RA55
RA45
15m
2
11m
2
11m
2
9.0m
2
8m
2
5.2m
2
20m
2
12.5m
2
A
A
Series
RA5, RA15, RA35, RA45, RA55
3
6
RA5
C
Remove the tube.
Motor
Limit Switch
Operating
Rating
Range
time
(W)
(revolution)
(min)
98
40 +/- 1
4
112
22,5 +/- 1
4
191
22,5 +/- 1
4
191
4
22,5 +/- 1
198
22,5 +/- 1
4
6
1
4
5
RA15, RA 35, RA45, RA55
7
2

Advertenties

loading

Deze handleiding is ook geschikt voor:

Ra35Ra45Ra55Ra15