Figure 20
Troubleshoot
CAUTION
Contact a EUROM authorized professional:
The LCD can display the following error codes:
Error
Problems
Code
CO
Indicates the condensed
water drainage hose
and the heat exhaust
hose need to be
connected.
Er0
Temperature sensor
cutting out.
Er1
DC motor cutting out.
Er2
Indoor unit water tank is
full. Buzzer beeps 10
times and the device
stops.
Er3
Water pump error for 2
minutes. Buzzer beeps 10
times and the device
stops.
36
in the event of regularly recurring errors;
if the errors are not solved.
Figure 21
Solution
1. Connect water drainage
hose.
2. Connect heat exhaust
hose.
3. Press and hold '+' and '-'
for 3 seconds.
Contact a EUROM
authorized professional.
Contact a EUROM
authorized professional.
Drain the water tank from
the indoor unit.
Contact a EUROM
authorized professional.