1. Emissivity value
2. Time
3. Battery capacity
4. Image target centre temperature
5. Target centre

8. Operation

a) General operation steps
1 Long press the Back/Power button for 3 seconds to display the start-up screen. After start-
up, the thermal image will be displayed on the screen.
2 Target an area or object with the thermal imaged points and check the thermal image. The
relative temperature is shown from hot to cold through the color table (corresponding to light
to dark). The infrared temperature reading (shown above the thermal image) indicates the
temperature of the target measuring point aimed at the cross cursor on the display screen.
3
2
6. Color bar
7. Minimum temperature reading position
8. Maximum temperature reading position