11. OPERATION
a) Basic functions
Only keep the camera head and goose neck (1) in voltage free liquid. The goose neck
should not be immersed on the other side of the "IP67 max. water level" marking.
The endoscope is suited for inspection only in voltage-free systems. The camera head
is made of metal and can cause short-circuiting. For safety reasons, make sure all
system components are voltage-free before inspection.
Avoid heavy mechanical loads and/or vibrations. Do not exceed the minimum bending
radius of 45 mm.
• Press the on/off button (10) to switch on the device. The Power LED (3) is switched on. The
camera picture appears on the screen.
• Four LEDs are integrated into the camera head.
• Keep the ↑ button pressed for approximately two seconds to rotate the picture by 180º .
• Keep the ↓ button pressed to zoom in.
Attachments
• Fix one of the three attachments (magnet, hook, mirror) if needed to the narrow indentation
under the camera head.
• Make sure that the attachment's fastening ring is closed before use.
Triangle attachment point
A triangle attachment point is attached above the screen. Attach it to a carrying strap if needed
(not included in the delivery scope) to enable freehand operation.