PANEL FIXING

Fix the unit tightly, the plastic panel must be mounted using only and exclusively the screws
provided (holes position in Fig. C)
To prevent the deformation of the grid, be careful not to overtighten the screws.
Fig. C
EN

FRESH AIR SYSTEM AND REMOTE AIR DISTRIBUTION

The side openings allow the separate realization of an external air intake duct for the
renewal and of an air hose duct for an adjacent room.
FRESH AIR
Remove the film on the sheet indicated with letter A in Fig. D.
Use the flange Ø60 mm (optional) and connect the pipe with anti-condensate insulation;
the use of a fan for the duct (optional) must be provided with non-return valve and filter to
prevent dust.
REMOTE AIR DISTRIBUTION
Remove the film on the sheet indicated with letter B in Fig. D.
Use the flange Ø150 mm (optional) and connect the pipe for air distribution in the adjacent
room.
It is recommended the closing of the air vent on the panel in correspondence of the duct
of remote air distribution.
5