INTENDED USE
This product is a camera attachment for the endoscopes BS-500 and BS-1000T (neither included in the
scope of delivery) for visual troubleshooting or inspection of voltage-free systems and installations. The
product is especially suited for inspecting pipelines.
The flexible camera neck permits the camera located on the tip to reach otherwise inaccessible positions.
) button, the camera angle can be adjusted between 0° and 90°. The light-emitting
With the (
diodes located in the camera head permit recording even in absolutely dark areas. The brightness can be
regulated via the connected endoscope.
The waterproof camera neck and head are suitable for use in liquids (no acidic or basic solutions). Use on
persons or animals as well as in potentially explosive areas is not permitted. The device is supplied with
power via the connected endoscope.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged. In addition,
improper use can cause hazards such as short circuiting, fire, electric shock etc. Read the instructions
carefully and keep them. Make this product available to third parties only together with its operating
instructions.
This product complies with the statutory national and European requirements. All company names and
product names are trademarks of their respective owners. All rights reserved.
DELIVERy cONTENT
• Endoscope camera
• Lens cap
• Operating instructions
SAFETy INSTRUcTIONS
Read the operating instructions carefully and especially observe the safety information.
If you do not follow the safety instructions and information on proper handling in this
manual, we assume no liability for any resulting personal injury or damage to property.
Such cases will invalidate the warranty/guarantee.
a) persons / product
• Hold the camera neck and head only in voltage-free liquids.
• The connecting socket may not come into contact with liquids.
• The endoscope is suited for inspection only in voltage-free systems.
• The camera head is made of metal and can cause a short circuit.
• For safety reasons, make sure all system components are voltage-free before inspection.
• Replace the lens cap on the camera lens when the camera is not in use.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become dangerous
playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity,
moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and protect it
from any accidental use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height can
damage the product.
• Also observe the safety and operating instructions of any other devices which are connected
to the product.
• For installations in industrial facilities, follow the accident prevention regulations of the
government safety organization or the corresponding authority for your country.
• Do not operate the device immediately after transferring it from a cold to a warm room. This
can cause condensation which may, under adverse circumstances, destroy the device. Leave
the device turned off until it has reached room temperature.
b) miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the device.
• Maintenance, modifications and repairs are to be performed exclusively by an expert or at a
qualified shop.
VERSION 05/13
ITEm NO.: 10 35 59 2m/5.8mm
If you are not sure about the correct connection or use, or if questions arise which are not covered by
these operating instructions, please do not hesitate to contact our technical support or another qualified
specialist.
Voltcraft®, Lindenweg 15, D-92242 Hirschau, Tel. +49 180/586 582 7.
OpERATION
Do not exceed the minimum bending radius (see "Technical Data").
Do not submerge the camera neck past the marking "MAX Water Level".
a) General use
• Carefully connect the connecting socket on the camera neck to the plug on the upper part of the
endoscope.
• Make sure that the connecting socket is perfectly aligned with the plug's pins. There is an arrow
imprinted on the connecting socket. This arrow must point to the endoscope's display.
• Turn the fastening ring clockwise to lock.
• Before using the endoscope camera remove the lens cap.
• Turn on the endoscope.
• Tips on adjusting the LED brightness are available in the endoscope user manual.
• Turn off the endoscope after use and remove the endoscope camera from the endoscope.
• Turn the fastening ring counter clockwise and disconnect the two components.
b) Adjusting the camera angle
You can adjust the camera angle between 0° and 90° using the (
following positions:
= 0° (front) / green indicator lamp lights up
= 90° (side) / red indicator lamp lights up
mAINTENANcE AND cLEANING
• Besides cleaning, the device is maintenance-free.
• Never fully submerge the endoscope camera in water.
• To clean the camera lens, use a small brush or cotton swabs.
• Use a damp, soft, antistatic and lint-free cloth for cleaning. Do not use any abrasive or chemical cleaning
agents. Dry the endoscope camera after cleaning.
• After use, replace the lens cap.
• Let the endoscope camera dry before replacing the lens cap.
DISpOSAL
Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
TEchNIcAL DATA
Fits ..................................................................... BS-500, BS-1000T
Camera Ø .......................................................... 5.8 mm
Field of view ....................................................... 55°
Camera angle .................................................... 0/90°
Resolution .......................................................... 320 x 240 px
Light ................................................................... 4 LEDs; 4200 lux at 20 mm
Bending radius ................................................... >5 cm
Operating conditions .......................................... -20 to +60 °C, max. 95 % RH (non-condensing)
Storage conditions ............................................. -20 to +60 °C, max. 95 % RH (non-condensing)
Protection Class ................................................ IP67 (camera, camera neck)
102736
103558
Item number
Length
3 m
1 m
2 – 6 cm
2 – 6 cm
Focus depth
Weight
300 g
130 g
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© copyright 2013 by Voltcraft®
) button. Please note the
103559
2 m
2 – 6 cm
200 g
V1_0513_02-Jh

Advertenties

loading

Deze handleiding is ook geschikt voor:

10 35 5810 35 59