Download Inhoudsopgave Inhoud Print deze pagina

References For Protecting Devices And Cable Specification - AQUARK AQUA FORTE MR. SILENCE SC947 Handleiding

Inverter warm
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Distribution Box (Customer prepare)
Power Supply
230V 50Hz
Earthing
b. For power supply: 400V 50Hz
Distribution Box (Customer prepare)
Power Supply
400V 50Hz
Earthing
Note: 1)
Must be hard wired, plug is not allowed.
2) The swimming pool heat pump must be earthed well.

4. References for protecting devices and cable specification

MODEL
Rated Current (A)
Breaker
Rated Residual
Action Current (mA)
Fuse (A)
Power Cord (mm
Signal cable (mm
※ Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire diameter must be
increased. The signal cable can be extended to 50m maximum.
Fuse
Breaker
Fuse
Breaker
SC947
10.5
30
10.5
2
)
3x1.5
2
)
3x0.5
Swimming Pool Heat Pump Wiring Board
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Cord
SC948
SC949
12
14.5
30
30
12
14.5
3 x 2.5
3 x 2.5
3×0.5
3×0.5
10
SC950
SC951
18
21
30
30
18
21
3 x 4
3 x 4
3×0.5
3×0.5
SC952
9
30
9
5 x 2.5
3×0.5

Advertenties

Inhoudsopgave
loading

Inhoudsopgave