Download Print deze pagina

KIOUR RN5+ Handleiding pagina 9

Thermostaat koelvak - vriesvak

Advertenties

Beschikbare talen

Beschikbare talen

CHIILER THERMOSTAT
Model FSD3
ATTENTION
Read carefully these instructions before installing and using this device and keep them for future reference. Attention to installation and electrical wiring. Use this
device only as described in this document and never use itself as a security device. The device must be disposed of in accordance with local standards for the collection
of electrical and electronic equipment.
DECRIPTION
FSD3 is a thermostat for chiller cabinets, suitable for all applications and has the following specifications: one NTC / PTC temperature sensor which controls the room
temperature; 3 indication digits with resolution 0.5°C and 4 buttons; one digital input for controlling the cabinet's door; 3 relays: compressor 30Α 250VAC, fan 10Α 250VAC,
ON/OFF 10Α 250VAC; a buzzer in case of an alarm; it
(see page 2 – Serial input of the thermostat).
THERMOSTAT'S DIMENSIONS
ATTENTION: Read carefully the technical specifications and make sure that the working conditions are appropriate. According to safety standards, the device must be fastened
in such a way that it cannot be removed without the use of tools.
Dimensions are in mm. The device is mounted in panel hole 29x71mm and it is restrained with plastic side brackets.
INDICATIONS AND BUTTONS FUNCTION
Display indications
compressor ON
dFr
deFrost ON
fan ON
alarm ΟΝ
malfunction ON
For more indications regarding the alarms please see the alarm's table at page 3.
ADJUSTING ROOM'S TEMPERATURE – SET POINT
17. Press
to display the first parameter SPo.
18. Press
to display its value. With
19. Press
to save the new value. The cabinet is working properly with the new adjustment.
INDUSTRIAL FACTORY SETTINGS OF CABINET
25. Choose from the following table the corresponding program of your cabinet.
26. Press
to display the first parameter SPo. Press 4 times
27. Press
to display its value and press
28. Press
again to exit the parameter menu. All appropriate settings are now stored and the cabinet is working
Cabinet's model
Counters RU
Saladette / Glass door RU
ON / OFF CABINET
9.
Press for 3 seconds
can connect to the monitoring and controlling network CAMIN via serial input using an interface with MODBUS protocol
or
change its value.
to enter the cabinet's program. Press
to activate or deactivate the cabinet
and the parameter Cod is displayed.
to store the cabinet's program to
KIOUR
Keyboard
enter/exit the parameter's menu
confirm new value of a parameter
display the parameter's value
manual deFrost
down arrow
mute buzzer
ON/OFF cabinet
up arrow
parameter
Cod.
properly.