PARAMETER'S TABLE
No
code
description
1
SΡo
SET POINT: room temperature setting
2
ALo
Low alarm room threshold
3
AΗi
High alarm room threshold
4
dr1
Time between two successive defrost
5
Cod
Access code to the following parameters Cod = 22.
6
diF
Differential of room temperature SPo (thermostat delay)
7
dd2
Defrost duration. Manual defrost lasts 20 minutes.
8
dΡ3
Dripping timer, where the compressor is OFF after defrost
Display indication during defrost
9
dY4
0
= indication of room's temperature
1 to 99 minutes = indication dFr from 1 to 90 min counting from the beginning of defrost
Defrost end temperature
Defrost end temperature is the room temperature. Automatic defrost does not start if the
10
dE5
evaporator temperature is greater than the defrost end temperature dE5.
Manual defrost starts regardless of the room temperature and ends after 20 minutes.
11
dt6
(not in use)
12
AF1
(not in use)
Time delay in activating "AΗi" and the buzzer. This setting does not apply to "ALo", sensor
malfunction and door alarm.
13
At2
0 = immediate buzzer activation
1 to 120 minutes = delay in buzzer activation
14
Fo1
(not in use)
Evaporator's fan operation.
During defrost the fan operates.
15
Ft2
-1 =
continuous function
0 =
parallel with the compressor
16
tSd
delay of room temperature on screen
17
Co1
(not in use)
18
CP2
Compressor's minimum time OFF
Compressor's operation in case of room's sensor malfunction
19
CF3
0 = 40% ΟΝ compressor (3 minutes ΟΝ, 4 minutes OFF)
1 = ΟΝ compressor constantly
Serial input operation
0 = operates with CAMIN network and key memory
20
UFu
1 = connection with an external device for alarm output
ATTENTION: when parameter Add is different than zero, the UFu parameter automatically
is programmed to zero.
21
SE1
Room sensor offset
22
SE2
(not in use)
23
oS2
(not in use)
24
LSP
Lower setting limit of SPo
25
HSP
Maximum setting limit of SPo
Temperature measurement unit: toggling between °C/°F do not adjust the SPo automatically,
it must be changed by the user
26
C_F
0 = °C
1 = °F
Sensor type NTC/PTC
27
SEn
0 = PTC
1 = NTC
28
trE
Response time of the device on network
29
Add
Device address on network
30
diP
(not in use)
Door switch operation
0 = OFF
1 = NO (normally open)
31
Odo
2 = NC (normally close)
If the cabinet's door remains open for 2 minutes, the alarm
compressor stops.
,
where 0 = defrost is deactivated.
dor
is activated and the
INDUSTRIAL FACTORY SETTINGS
min
max
UOM
COUNTERS RU
Program 31
LSP
HSP
°C/°F
-50.0
AHi
°C/°F
ALo
150
°C/°F
0
12
hours
0
255
-
0.1
25.5
°C/°F
1
90
minutes
0
10
minutes
0
99
minutes
0.0
25.5
°C/°F
0
120
minutes
-1
0
-
0
20
sec
0
4
minutes
0
1
-
0
1
-
-9.9
+15.5
°C/°F
-50.0
HSP
°C
LSP
150
°C
0
1
°C/°F
0
1
-
0
100
msec
0
255
-
0
2
-
SALADETTE RU
Program 32
0.0
3.0
-5.0
-5.0
+15.0
+15.0
4
4
31
32
3.0
3.0
25
25
0
0
25
25
12.0
12.0
20
20
-1
-1
0
0
2
2
0
0
1
1
0.0
0.0
0.0
3.0
+10.0
+10.0
0
0
1
1
20
20
1
1
0
0
16

Advertenties

loading