15. VERBINDINGEN
15.1 XT130C – 12V AC/DC OR 24V AC/DC
Input: 4÷20mA
0÷1V / 0÷10V
DI
PT100
7
7
8
9
10
PTC / NTC
7
8(3)A250V
8(3)A250V
1
2
3
4
5
6
Line
Sonde: Pt100
Thermokoppel J, K, S
= 7 – 9 (8);
24Vac/dc voeding:
11-12
15.2 XT130C – 230V AC OR 115V AC
PTC / NTC
DI
PT100
9
10
11
12
8(3)A250V
8(3)A250V
1
2
3
4
5
6
7
8
Line
Sonde Pt100
Thermokoppel J, K, S
=9 –11 (10);
115Vac voeding:
7-8
15.3 XT131C – 12VAC/DC OR 24VAC/DC
Input: 4÷20mA
0÷1V / 0÷10V
DI
PT100
7
8
7
8
9
10
PTC / NTC
7
8
8(3)A250V
8(3)A250V
8(3)A250V
1
2
3
4
5
6
LOAD 1 LOAD 2 ALARM
Line
Sonde Pt100
Thermokoppel J, K, S
= 7 – 9 (8);
24Vac/dc voeding:
11-12
15.4 XT131C – 230V AC OR 115V AC
PTC / NTC
DI
PT100
9
10
11
12
8(3)A250V
8(3)A250V
8(3)A250V
1
2
3
4
5
6
7
8
LOAD 1 LOAD 2 Alarm
Line
Sonde Pt100
Thermokoppel J, K, S
=9–11 (10);
115Vac voeding:
7-8
XT130-131C_V2.doc
Installing and Operating Instructions
Installing and Operating Instructions
8
9 10
8
9 10
11 12
Hot-KEY
= 7(+); 9(-)
9 10 11 12
Input 4÷20mA
0÷1V / 0÷10V
9 10 11 12
Hot-KEY
= 9(+) - 11(-)
9 10
9 10
11 12
Hot-KEY
= 7(+); 9(-)
9 10 11 12
Input 4÷20mA
0÷1V / 0÷10V
9 10 11 12
Hot-KEY
= 9(+) - 11(-)
16. STANDAARD INSTELLINGEN
COD
Name
Set
Set point
db
Dead band
LS1
Minimum set point
US1
Maximum set point
S1C
Action type output
Ac
Anti-short cycle delay:
on
Minimum time a stage stays switched ON
ono
Minimum time between 2 following switching
ON of the same load
ALC
Alarm configuration
ALL
Minumum alarm (ALC=rE)
(ALC=Ab)
ALU
Maximum alarm (ALC=rE)
(ALC=Ab)
ALH
Alarm recovery differential
ALd
Alarm delay
dAO
Alarm delay at start up
So1
Output1 status with faulty pr.
So2
Output2 status with faulty pr.
tbA
1
Alarm relay disabling
AS
1
Alarm relay polarity
Lci
2
Start scale with current or voltage input
Uci
2
End scale with current or voltage input
OPb
Probe calibration
rES
Resolution
UdM
Measurement unit
PbC
Kind of probe
P3F
3
rd
wire presence
HES
Energy saving differential
i1F
Digital input configuration
i1P
Digital input polarity
did
Alarm delay for dig. input
Adr
Serial address
OnF
oFF function enabling
Ptb
Parameter table
rEL
Software release
Pr2
To access the Pr2
1
Enkel voor XT131C
Enkel voor toestellen met 4÷20mA of 0÷1V of 0÷10V
2
FRIGRO NV
DRIESLAAN 10
8560 MOORSELE
tel. +32 - 56419593 - fax +32 - 56403155
XT130C – XT131C
XT130C – XT131C
Range
LS1÷US1
-Full Sc./ Full Sc.
Down Sc./ Set
Set/ Full Sc.
in= Inverse; dir=direct
0÷250 sec
0÷250 sec
0÷120 min
rE=relat.; Ab= absolute
0 ÷ |Start Sc.-Set|
Start Sc.÷ ALu
0 ÷ |Full Sc.-Set|.
ALL÷ Full Scale
0÷Full scale
0÷999 min
0÷23h 50min
oFF=open on=closed
oFF=open on=closed
no; yES
CL÷oP
-1999÷1999
-1999÷1999
-Full Sc./ Full Sc.
in=NO; dE=0,1; cE=0,01
temp
(
.)
°C=°C; °F= °F;
current/voltage
(
)
0=°C; 1=°F; 2=RH; 3=bar;
4=PSI, 5=off
Pt=Pt100; J=tcJ; c= tck; S=tcS;
Ptc=PTC; ntc= NTC; 0-1=0÷1V;
10= 0÷10V; cur=0÷20mA
no=2 wires;
yES=3 wires
Down Sc./ Full Sc.
c-H / oFF / AuS / HES / EAL
/ bAL
cL=closed; oP=open
0÷120m
0÷247
no=not enabled;
yES=enabled
Readable only
Readable only
Readable only
1592002230
°C/°F Lev
0/32
-
1/2
Pr1
min
Pr2
max
Pr2
in
Pr2
0
Pr2
0
Pr2
0
Pr2
rE
Pr2
10.0/ 20 Pr2
10.0/ 20 Pr2
2.0/4
Pr2
15
Pr2
1.3
Pr2
oFF
Pr2
oFF
Pr2
yES
Pr2
oP
Pr2
various Pr1
various Pr1
0.0
Pr1
in
Pr2
various Pr1
various Pr1
no
Pr2
0
Pr2
EAL
Pr2
cL
Pr2
0
Pr2
1
Pr2
no
Pr2
--
Pr2
---
Pr2
321
Pr1
3/3