Note: If there is not enough water added, incomplete sterilization may occur� If the unit
was not able to sterilize completely, it will beep and the indicator light will flash for one hour�
If this happens, wait 10 minutes to allow unit to cool, then add water to the solid FILL LINE
of the measuring cup (110 mL), pour the water onto the heating plate and restart the
sterilization cycle�
Dry Only
A
Press the Dry Only Button� The appliance will beep one time and the drying cycle
will start�
B
When the drying cycle is complete, the appliance will beep 5 times and
switch off automatically� This cycle lasts approximately 45 minutes�
Note: Any cycle can be stopped at any time by pressing the power button�
CAUTION: If it is necessary to drain water always
POUR AWAY FROM YOU, as shown by the symbol
on base�
CLEANING THE APPLIANCE
CAUTION: Unplug from outlet and allow to cool for 60 minutes before
cleaning� DO NOT IMMERSE IN WATER�
Clean at least once a week when in regular use�
BASE AND HEATING PLATE: Wipe all surfaces with a damp cloth or sponge�
TRAY, LID, LOWER RACK AND MEASURING CUP: Clean in hot, soapy water and rinse well,
or in a dishwasher (top rack only)� Allow to air dry�
Note: DO NOT use scouring pads, abrasives, bleach or solvents for cleaning�
DO NOT disassemble base� There are no serviceable parts inside�
DESCALING
CAUTION: Unplug from outlet and allow to cool for 60 minutes before descaling�
Mineral deposits, like limescale, may form on the metal heating element in the base� As the mineral
deposits build, it can slow or disrupt the sterilization cycle� Depending on the water type in your
area, mineral deposits may vary in appearance but the harder the water, the quicker it builds up�
Mineral deposits are not known to be harmful, but they may impair the function of appliances
or damage components� Using non-mineral bottled water can help prevent buildup, but regular
descaling is needed for best performance� To remove the mineral deposits, follow the steps below�
1
Remove the lower rack, tray and lid from the base�
2
Descale utilizing a mixture of vinegar/water:
A
Fill measuring cup to the dashed line (80 mL) with white vinegar�
B
Add an additional 30 mL of non-mineral bottled water to reach the solid FILL LINE
of the measuring cup (110 mL total)�
C
Pour the mixture ONTO THE HEATING PLATE
�
5