Example for the heating mode
• If the room thermostat serves a frost monitor and should keep the room temperature of e.g.
a storage room or cellar above +5 °C, connect the front outlet of the room thermostat to a
heater, such as a convector.
• Turn off the room thermostat and check which operating mode is currently installed (" " =
Heating mode, "
" = Cooling mode).
• Choose Heating mode as the operating mode.
• Switch on the room thermostat. The control-LED (1) must now light up (LED is red = the front
outlet is deactivated, LED is blue = the front outlet is activated).
• Set a temperature limit of +5 °C with the buttons " " (7) and " " (8). The room thermostat is
therefore ready for operation.
• If the room temperature falls under +5 °C for longer than 1 minute, the room thermostat will
turn on the connected heater. The control-LED (1) lights up blue, and additionally the symbol
" " appears.
The time period of 1 minute serves to prevent the connected heater from being
switched on or off in succession too quickly.
• If the room temperature rises higher than +5 °C, the room thermostat turns off the connected
heater again. The control-LED (1) lights up red, and the symbol " " disappears again.
Example for the cooling mode
• If the room thermostat is to keep a room from excessively high temperatures, connect the
front outlet of the room thermostat to a ventilator for example (or a suitable air conditioner).
• Turn off the room thermostat and check which operating mode is currently installed (" " =
Heating mode, "
" = Cooling mode).
• Choose Cooling mode as the operating mode.
• Switch on the room thermostat. The control-LED (1) must now light up (LED is red = the front
outlet is deactivated, LED is blue = the front outlet is activated).
• Set a temperature limit of +25 °C with the buttons " " (7) and " " (8). The room thermostat
is therefore ready for operation.
• If the room temperature rises over +25 °C for longer than 3 minutes, the room thermostat will
turn on the connected ventilator (or an air conditioner). The control-LED (1) lights up blue,
and additionally the symbol "
" appears.
The time period of 3 minutes serves to prevent the connected air conditioner from
being switched on or off in succession too quickly.
• If the room temperature falls below +25 °C, the room thermostat will turn the connected
ventilator (or a air conditioner) off again. The control-LED (1) lights up red, and the symbol "
" disappears again.
Maintenance and care
• The product does not require maintenance. The product contains no parts that require servi-
cing. Therefore, do not open/dismantle it. Maintenance or repair may only be performed by
qualified personnel or a specialised repair shop.
• Before cleaning, disconnect the room thermostat from the power supply. To do this, pull it
completely out of the mains socket. Then disconnect the room thermostat from the connec-
ted device.
• To clean the product, a clean, dry and soft cloth is sufficient.
• Dust can be easily removed using a clean, soft and long-bristled brush and a vacuum clea-
ner.
Do not use abrasive cleaning agents, rubbing alcohol or other chemical solutions,
which may damage the casing or even impair operation.
Disposal
Electronic devices are recyclable waste and must not be placed in household waste.
At the end of its service life, dispose of the product according to the relevant statu-
tory regulations.
You thus fulfil your statutory obligations and contribute to protection of the environ-
ment.
Technical data
Connection data .......................................230 V/AC, 50 - 60 Hz
Connection power .....................................Resistive load: max. 3680 W (230 V/AC, 16 A)
..................................................................Inductive load: max. 460 W (230 V/AC, 2 A)
Devices with mainly resistive load are e.g., light bulbs, heaters, etc.
Devices with inductive load are, e.g., engines, control gears, conventional trans-
formers, energy saving bulbs, etc.
Switch type ...............................................Relay (single-pole)
Temperature setting range ........................+5 °C bis +30 °C
Accuracy ...................................................±1 °C
Backup battery .......................................... yes, built-in permanently (NiMH, 2,4 V, 40 mAh);
Enhanced protection against
accidental contact .....................................yes
Ambient conditions ................................... Temperature 0 °C to +40 °C; humidity 20% to 90%,
Dimensions ...............................................60 x 110 x 77 mm (W x H x D, including plug)
Weight ......................................................136 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing
in electronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is
prohibited. This publication reflects the technical state at the time of printing.
Copyright 2020 by Conrad Electronic SE.
Charging time approx. 8 - 12 h, Back-up time approx.
200 h
non-condensing
*1323077_V5_1020_02_m