7 Operation
DANGER
Risk of serious injury or death from carbon monoxide.
Never operate the product while a combustion vehicle engine is running in an enclosed
area (e.g., garage), or near other enclosed areas.
Important:
The following information applies to combustion engines:
– It is recommended to use the inverter when the engine is running. This is so that the
alternator can recharge the vehicle battery.
– Do not to discharge the vehicle battery faster than the alternator can recharge it. Mon-
itor the battery voltage and run the engine if needed.
– Do not start the vehicle engine when connected devices are in use.
Preconditions:
a
(If applicable) connected loads are switched OFF.
1. Connect the product to the auxiliary power socket.
à
The POWER indicator lights up.
2. Connect any loads and switch them on one by one.
à
For AC socket loads, you must first switch the socket power ON by pressing the
AC ON/OFF button.
8 Protection mechanisms
Protection
Description
Overload protec-
Triggers if connected loads are greater than rated output.
tion
Overload protection:
1. Remove any excess loads.
2. Reset (disconnect then reconnect) the inverter to resume use.
Fuse
Blown Fuse
■
The product is equipped with a non-replaceable fuse.
■
If the fuse blows, the product can no longer be used.
High voltage
Triggers if the input voltage is greater than 15.5 V ±0.5 V.
protection
1. Make sure the vehicle supply voltage is 12 V.
2. Reach a professional for help, if needed.
Low voltage pro-
If the input is <10 V ±1 V, the inverter shuts OFF to protect the car bat-
tection
tery from over discharge.
1. Disconnect the inverter and increase the vehicle battery voltage
(e.g., restart the motor so the alternator can recharge the battery).
2. Reconnect the inverter when the vehicle battery reaches 12 V.
Over temperat-
If the inverter temperature is 90°C ±5 °C, the inverter will switch OFF.
ure protection
1. Disconnect the product, allow the converter to cool down and then
reconnect it.
2. Do not place the inverter in areas of high sunlight or next to a heater.
9 Cleaning and care
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Clean the product with a dry, fibre-free cloth.
4
10 Disposal
This symbol must appear on any electrical and electronic equipment placed on
the EU market. This symbol indicates that this device should not be disposed of
as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-
back of waste. Conrad provides the following return options free of charge (more details on
our website):
■
in our Conrad offices
■
at the Conrad collection points
■
at the collection points of public waste management authorities or the collection points
set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply
in countries outside of Germany.
11 Technical data
Input ............................................... 12 V/DC 176 W max.
Output (AC socket)......................... 230 V/AC, 150 W max.
USB outputs ................................... Supports power delivery (PD):
Signal output form .......................... Modified sine wave
Continuous output power................ max. 150W
Peak output power.......................... 300 W
Efficiency at rated load ................... >85 %
Power consumption (without load) . 0.4 A (without load)
Cooling fan ..................................... yes (temperature controlled)
Fuse (not replaceable).................... max. 25 A
Enhanced protection against
accidental contact........................... Yes
Protection class .............................. II
Operating conditions....................... -10 to +45 °C, 20 - 85 % RH (non-condensing)
Storage conditions.......................... -10 to +45 °C, 20 - 85 % RH (non-condensing)
Dimensions (L x W x H).................. 143 x 81 x 79 mm
Weight ............................................ 343 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2987897_V3_0624_dh_mh_en 27021598967175307-2 I4/O3 en
USB-A:
(5 V/DC 3 A, 9 V/DC 2 A, 12 V/DC 1.5 A) 18 W
USB-C® 1:
(5 V/DC 3 A, 9 V/DC 3 A, 12 V/DC 2.5 A) 30 W
USB-C® 2:
(5 V/DC 3 A, 9 V/DC 3 A, 12 V/DC 2.5 A) 30 W
NOTE: If more than 1x USB output is connected, the
maximum output for all ports will be: 5 V/DC 3 A