Switching off the appliance
•
Press button to lower the flames and to switch off the burner.
•
Then press "OFF" button to switch off the entire unit, including the pilot flame.
•
If the appliance is not used for a longer period it is advisable that you turn off the gas valve in the gas pipe.
Important: if the pilot flame has gone out for whatever reason, you must wait at least 5 MINUTES before lighting
the pilot flame again.
Failure
If it looks as if the signals of the remote control are not properly received by the stove (receiver), it may be caused by:
•
Empty batteries: change the batteries.
•
An electronic problem: solve it by pressing the "RESET" button on the receiver.
•
If the appliance often switches off you should contact your installer.
Operation (remote control with EcoWave)
For the complete explanation of the operation via the SYMAX-remote control, please refer to the instruction manual supplied
separately.
Operation (optional Wanders EcoWave app)
It is possible to order the optional Wi-Fi module in order to operate the fireplace using the Wanders EcoWave app,
The app can be downloaded for free at the Apple App Store and/or the Google Play Store. Incidentally, the app can only be
used in combination with the SYMAX EcoWave remote control.
Control (manual control)
If the batteries are due for replacement or if the receiver is defect, you can also operate the hearth by hand. To do so, you need
to disconnect the ignition (piezo) cable of the receiver and slide it gently onto the piezo connection of the gas control block.
Lighting the fire and putting it out
1.
Open the gas stopcock which is mounted in the gas pipe leading to the
appliance.
2.
Press "O I" switch on the gas control block in the "I" position.
3.
Turn motor switch on the gas control block all the way to the right. The
switch will make a ticking sound.
Turn operating switch on the gas control block in the MAN position; an
4.
orifice becomes visible.
5.
Push the metal pin in the orifice with something like a small pen. The gas
will now flow to the pilot.
6.
While keeping the metal pin pressed in, press the (square) ignition fuse
(next to the "O I" switch) to ignite the pilot flame. Look through the glass to
see whether the pilot flame is burning.
7.
If the pilot flame is burning, keep the metal pin pressed for another 10
seconds and then release it. If the pilot flame dies, wait for another 5 minutes
before repeating the above steps.
8.
Turn operation knob to the "ON" position.
9.
Turn motor switch to the left to ignite the burner and to select the height
of the flames.
10. Turn motor switch all the way to the right to put out the fire; the pilot flame will keep burning.
11. If you want to put out the pilot flame as well, turn "O I" switch to the "O" position.
12. Close the gas tap.
GB