GB
Possible settings
By pressing the SET button you can switch quickly between MAN day temperature lamp ventilator night
•
temperature timer MAN.
•
MAN: this setting allows you to turn the flames manually higher or lower with the big-flame button or the small-flame
button .
•
Day temperature (): this mode allows you to set the desired daytime temperature; the remote control set will function as
a thermostat.
•
Night temperature (): this mode allows you to set the desired night temperature.
•
TIMER: this mode allows you to preset 2 switch-on and 2 switch-off times per 24 hours. If the night setting is on - - -, the stove
will burn on the pilot flame.
Setting the temperature
•
Select the day temperature or night temperature by briefly pressing SET button .
Now press SET button longer until the display starts flashing.
•
•
Preset the temperature with buttons or (5 ºC is the minimum day temperature).
Wait or press OFF button to switch back to the thermostat-controlled system.
•
•
In order to save the batteries you are advised to reset the night-temperature until the display shows the '- - -' signal.
Setting the timer function
Select the timer function by briefly pressing SET button a few times.
•
Now press the SET button longer until P1 () starts flashing.
•
•
Set the hours with button and the minutes with button .
•
Briefly press SET button for the next timing.
•
Once all 4 timings have been set, press OFF button to end the presetting.
Operation (standard remote control)
Igniting the fire
•
Open the gas turncock that is fixed in the gas pipe leading to the stove.
Press "O I" switch on the gas control block in the "I" position.
•
Turn control button on the gas control block to the ON position.
•
•
Simultaneously press buttons and on the handset. A short acoustic signal
indicates the start, and is followed by short acoustic signals (0.2 sec/signal, 1Hz.)
until the pilot flame and the chief burner are ignited. After the main burner has lit,
the flame height will automatically go to the maximum position.
Possible error messages
•
Long signals (0.8 sec. signal with 0.2 sec. interval) during lighting : batteries of the receiver are almost empty. (After hearing
this signal, you can switch on the appliance for about another 10 times.)
•
5 seconds continuous signal : error message. One of the cables may not be connected, or the "O I" switch is not in the "I"
position.
•
5 short signals (0.2 sec. signal with 0.2 sec. interval) : ignition of the pilot flame and the main burner has failed. Possible
cause: air in the pilot burner pipe.
Important: If the pilot flame has gone out you must wait at least 5 MINUTES before repeating the above-
mentioned steps.
Setting the height of the flames
•
After igniting the burner, the height of the flames will automatically reach the maximum position.
Press button continuously to lower the flames and to switch off the burner (putting the fire out: "STAND BY"). Press button
•
briefly to gradually lower the flames.
•
Press button to increase the flame height. Briefly press button to gradually increase the flames.
•
Simultaneously press button and button to turn off the rear burner.
•
Simultaneously press button and button to turn on the rear burner again.
•
It is not possible to have only the rear burner be lit.