Download Inhoudsopgave Inhoud Print deze pagina

Jung FM AS 10 UP Bedieningshandleiding pagina 9

Radiografische actor 1-kanaals
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

eNet
Radiografische actor 1-kanaals
Switch-on delay
Switch-off delay
Run-on time
Behaviour after the end of the
disabling function
Behaviour on voltage return
82581213
J:0082581213
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
0 s ... 24 h
Basic setting: 0 s
On
Off
no change
Last value
Basic setting: No change
On
Off
Last value
Configured brightness
Basic setting: Off
9/12
The load switches on after a
delay. Repeated switch-on
commands restart the delay
time. If the load has not yet
been switched on due to the
delay when a switch-off com-
mand comes, then the load
will remain off.
In Flashing operating mode,
the pause times are set using
this parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.
The load switches off after a
delay. Repeated switch-off
commands restart the delay
time. If the load has not yet
been switched off due to the
delay when a switch-on com-
mand comes, then the load
will remain on.
In Flashing operating mode,
the pulse times are set using
this parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.
As soon as a run-on time has
been entered, the actuator will
no longer remain on perma-
nently, but only for the length
of the run-on time. The run-on
time is restarted if actuation is
repeated. This parameter is
directly connected to the
"Manual switch-off of run-on
time" parameter.
Comment: The set times apply
to operation using radio trans-
mitters. The relay is switched
immediately when the Prog
button is pressed.
Behaviour of the output when
a block is removed.
Defines the behaviour of the
output after voltage return.
13.03.2014

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Fm as pf 10 up

Inhoudsopgave