eNet
Radiografische actor 1-kanaals
Timer behaviour, voltage
return
Switch-off warning
Priority, lock-out protection
Priority, restraint
Priority, wind alarm
Priority, sun protection
Priority, twilight
Switch-off on brightness
overshoot
82581213
J:0082581213
Off
Restart
Basic setting: Off
On, Off
Basic setting: Off
0...4
Basic setting: 1
0...4
Basic setting: 2
0...4
Basic setting: 3
0...4
Basic setting: 0
0...4
Basic setting: 0
On, Off
Basic setting: On
10/12
Specifies whether the timers
for switch-on delay, switch-off
delay and run-on time remain
off after voltage return or whe-
ther they restart. Directly con-
nected to the parameters
"Switch-on delay", "Switch-off
delay" and "Run-on time".
If the switch-off warning is
active, the light is not switched
off directly. The light goes off
30, 15 and 6 seconds before
permanent switch-off. During
the switch-off warning, a
switch-on telegram effects
direct switch-on. It is not pos-
sible to terminate the time
using a switch-off telegram.
Specifies the priority for
recalling and removing a sce-
ne of type Lock-out protection
for the channel.
Specifies the priority for
recalling and removing a sce-
ne of type Forced position for
the channel.
Specifies the priority for
recalling and removing a sce-
ne of type Wind alarm for the
channel.
Specifies the priority for
recalling and removing a sce-
ne of type Sun protection for
the channel.
Specifies the priority for
recalling and removing a sce-
ne of type Twilight for the
channel.
Allows automatic switch-off
according to the brightness. If
the parameter is On, then the
light controller switches off
automatically when the
brightness setpoint is greatly
exceeded. This parameter is
not yet active, as a light con-
troller has not yet been imple-
mented.
13.03.2014