ROUBLESHOOTING
Fault
The fire doesn't burn well
Glass blackens quickly
A strange odour and smoke
develops during first use
Condensation
Smoke hindrance
Chimney fire
All manuals and user guides at all-guides.com
Cause
Damp wood
Inappropriate fuel
Poor chimney draught (min 12 Pa)
Insufficient combustion air
Damp wood
Inappropriate fuel
Filled too much wood
Insufficient combustion air
Baking in of the paint
High difference in temperature
Poor chimney draught (min 12 Pa)
Fuel isn't entirely burnt
Innapropriate fuel
Overcharge
Poor maintenance
SAEY
Home & Garden NV.
Industrielaan 4
B – 8501 KORTRIJK - Heule
Belgium
www.saeyheating.com
Solution
Use dry wood (moisture content ≤20%)
Only use recommended fuels
Check the air-tightness of the flue
Close the chimney's cleaning hatches
Clean the flue
Check diameter flue outlet and supply of
combustion air
Check if extractor fans are operating in the
same room
Use dry wood (moisture content ≤20%)
Only use recommended fuels
Do not fill more than 2-3 wood logs
Check diameter flue outlet and supply of
combustion air
Check if extractor fans are operating in the
same room
The odour and smoke will dissapear after a while
Open the door for 2-3 min when lighting the fire.
Do not leave the fire unattended!
Check the air-tightness of the flue
Close the chimney's cleaning hatches
Clean the flue
Only fill wood logs when flames are dying out
Immediately close the air supply and contact the fire
department