3
before first use
Prior to using the machine for the first time please check whether the electricity and supply water specifications match
the values indicated by the installation instructions for the appliance.
Remove all packaging materials inside the machine.
Fill the salt reservoir and fill up with water until it almost overflows. Set the water hardness setting.
Fill the rinse aid reservoir.
FILLING THE SALT RESERVOIR
For a good washing result, the dishwasher needs soft, i.e. less calcareous water. Otherwise, white lime residues will remain
on the dishes and the interior of the dishwasher. This has a negative effect on your applinace's washing, drying and shining
performance. For this purpose, dishwasher salt is used.
• Remove the basket and unscrew the cap of the salt reservoir (1).
• Fill with salt till the overflow level, about 1.0 kg (2).
• Fill the reservoir before first use with water. It is normal for a little water to flow out of the opening when doing this.
• Screw the cap back on firmly.
ATTENTION!
• Remove any spilled salt and run a full program
to prevent corrosion to the bottom.
• Refill the salt reservoir when the indicator light
of the salt reservoir lights up.
SETTING THE SALT CONSUMPTION
To find out the water hardness level in your area, contact your local water company. Adjust the salt consumption according
to the table on the next page.
Note! Hardness level is adjusted to level 4 as a factory setting.
• Close the door and switch on the machine.
• Press and hold the Program button P for 5 seconds to enter the mode for setting the salt consumption. This must be set
within 60 seconds after turning the machine on.
• Set the level by pressing Program button P repeatedly. Use the table of water hardness level settings.
• After adjusting the level of water hardness, press the On/Off button to confirm and store the setting. If the setting is not
confirmed, it is stored automatically after 5 seconds.
Table of water hardness level settings
Water
German hardness
hardness
°dH
1)
level
H1
0-5
H2
6-11
H3
12-17
H4 *
18-22
H5
23-34
H6
35-45
1)
German degree of measurement for the water hardness
2)
millimol, international unit for water hardness
3)
Each program cycle with a regeneration process consumes additional 2.0 litres of water. The energy consumption
increases by 0.02 kWh and the program extents by 4 minutes.
*
factory setting
1
Open
International
Program indicator
indication hardness
hardness level
mmol/l
2)
0-0.9
● indicator light RINSE on
1.0-2.0
● indicator light FAST 90 MIN on
2.1-3.0
● indicator light FAST 90 MIN on
● indicator light RINSE on
3.1-4.0
● indicator light DELICATE on
4.1-6.1
● indicator light DELICATE on
● indicator light RINSE on
6.2-8.0
● indicator light DELICATE on
● indicator light FAST 90 MIN on
2
Regeneration
occurs every X
program cycles
3)
none
10
5
3
2
1