9.6 Supplementary installation instructions per appliance

9.6.1 Ivar 8 Low

9.6.1.1 Flue gas exhaust

The flue gas exhaust has a 6" diameter connection. The draining connection can be achieved by means of a fixed
pipe of 6". The flue gas exhaust can be connected at the top or rear of the appliance (see Appendix 2, fig. 2).
In case of a connection at the rear, please proceed as follows:
Ø
Remove the 2 bolts from the exhaust ring mounted at the top of the appliance.
Ø
Remove the bolts from the plate at the rear of the appliance.
Ø
Mount this plate on the top of the appliance, on the location where the exhaust ring used to be.
Ø
Mount the exhaust ring at the rear of the appliance by tightening the 2 bolts.

9.6.1.2 Outside air connection

An outside air connection is available for this appliance as accessory. Assembly always takes place at the bottom
of the appliance. In case of this appliance, supply is possible via the rear and the back.
When installing an Ivar 8 Low
!Caution
the steps described under the heading 'Outdoor air connection pre-mounted'.
Outdoor air connection not pre-mounted:
When mounting the outside air connection, please proceed as follows (see Appendix 2, fig. 9a + 9b):
Ø
Loosen the 5 bolts that are pre-mounted on the outside air connection.
Ø
Bring the outside air connection against the plate on the bottom of the appliance.
Ø
Then re-tighten the 5 bolts.
Ø
Fasten the tray for the benefit of the rear connection with 4 bolts.
Ø
Connect the flexible hose to the round 'pipe opening' of the above-mentioned tray.
The flexible hose can only be fed from the rear.
The round pipe opening for the benefit of the lower connection is not needed during installation and should be
Caution!
disposed of responsibly.
Outdoor air connection pre-mounted:
Ø
Connect the flexible hose (Ø 80 mm) to the round 'pipe mouth' of the outdoor air connection.
In the case of the Ivar 8 Low
!Caution
an airtight connection of the flexible hose to the round 'pipe mouth' by using heat resistant sealant.
If you want to disassemble the outdoor air connection, you should perform the above-mentioned steps in reverse
order.
40
EA
RS
/ Ivar 8 Low
RS
appliance, the outdoor air connection is pre-mounted at delivery. If so, observe
RS
, you are dealing with a fully closed system. This means that you must always ensure