Frequency "Hz"
Range
5 - 9.999 Hz
99.99 Hz
999.9 Hz
9.999 kHz
Signal level: > 8 Vrms
Pulse ratio "%"
Range
20.0 - 80.0%
Frequency range: 5 Hz - 10 kHz, Signal level: >8 Vrms
Displays the positive half-wave in %
Diode test
Test voltage
Approx. 3.3 V
Overload protection: 600 V; Test voltage: <1.3 mA
Acoustic continuity tester
Test voltage
Approx. 1 V
Overload protection: 600 V, Measurement range max. 600 Ω;
Continuous tone <50 Ω, No tone ≥50 Ω
Test current: <0.5 mA
Response time 1 ms
NCV non-contact AC voltage test
Test voltage
>230 V/AC
Frequency: 50 - 60 Hz
Never exceed the maximum permitted input values. Never touch circuits or parts of circuits when
they may contain voltages greater than 33 V/ACrms or 70 V/DC! Fatal hazard!
62
Resolution
0.001 Hz
0.01 Hz
0.1 Hz
0.001 kHz
Resolution
0.1%
Resolution
0.001 V
Resolution
0.1 Ω
Distance
max. 50 mm
Accuracy
±(2% + 3)
Accuracy
±(1.5% + 8)