Problem
Condensation on the
glass shelf above the
drawers in the
refrigeration
compartment.
Water is
dripping/leaking from
the refrigerator:
Symbol D flashes.
Door does not open
easily.
LED lighting does not
work.
Appliance makes a
noise.
If you are unable to solve the problem then contact the service centre. When you do so, state the
type, model and serial number shown on the type plate or label on the inside of the appliance.
Cause/Solution
Check that the door is closed properly and seals properly.
This is a temporary problem that cannot be avoided entirely in periods
of high ambient temperatures and high humidity. The problem
disappears when the temperature and humidity return to normal levels.
We recommend that you clean the drawers more frequently and
occasionally wipe off any drips.
Pack food in bags or other air-tight packaging.
Clogged water discharge opening or water dripping past the water
gutter.
Clean the blocked opening, e.g. using a plastic straw.
If a thick layer of ice builds up, defrost the appliance manually (see
'Defrosting the Appliance').
The door has been opened for too long or too frequently.
The door does not seal properly (the seal is dirty, the door is
misaligned or the seal is damaged, etc.).
Too much fresh food has been put in at the same time.
You are trying to open the appliance's door just after you have closed the
door. Then opening the door is difficult. When you open the door, cold
air escapes from the appliance and is replaced by warm air from the
surroundings. As this air cools a slight vacuum is created that makes it
more difficult to open the door. The situation returns to normal after a few
minutes, and the door opens easily again.
Consult a service technician about LED lighting that is not working.
For safety reasons, you are not allowed to repair LED lighting yourself.
This product contains a light source of energy efficiency class E.
The appliance is cooled by a refrigeration system with a compressor
(and with some models, also a fan) that makes a noise. The noise
level depends on the installation of the appliance, its correct use and
its age.
When you connect the appliance to the power supply the noise made
by the compressor or flowing refrigerant may be slightly louder. This
is not indicative of a defect, and has no effect on the service life of
the appliance. The appliance will make less noise after a while.
The appliance may be temporarily noisier after the door has been
opened for too long or too frequently, a large quantity of fresh food
has been put in the appliance or the intensive freezing or intensive
cooling function has been activated.