Start the installation only when the following conditions are met:
You are satisfied with the colour, dimensions and capacity of the radiator, this information is available on
the product's technical data sheet.
The radiator has no transport damage or visible defects.
The wall against which the radiator is placed has sufficient bearing capacity, this means radiator and water capacity. The wall
fixings supplied should only be used in brick or concrete. For other applications, use wall fixings required for the wall. Also make
sure that the radiator is fixed to the wall with the brackets, non-tightened nuts or bolts can have serious consequences if the
radiator comes off the wall, think not only of yourself but also of small children.
If you plan to equip the radiator with an electric heating element, you should respect the applicable safety zones for wet areas,
they are there for your safety. The installation manual of the heating element indicates these zones where this is possible.
When only using the radiator electrically, the radiator should NOT be 100% FILLED with water. Because water expands during
heating, a fully filled radiator may create such high pressure that the radiator casing is damaged or there is a risk of explosion.
The instructions for the electric heating element explain how to avoid this. MAXIMUM PRESSURE 3.0 bar - MAXIMUM WATER
TEMPERATURE: 95 C°
If you have any doubts about the feasibility of the installation, consult a professional, he will be happy to help you.
THIS RADIATOR MUST ONLY BE FILLED WITH WATER INCLUDING
corrosion and scale inhibitor. It is strongly recommended to flush the radiator prior to installation. Failure to follow these steps
increases the risk of leaks in the system and voids the radiator's warranty.
IN FREEZING TEMPERATURES, THE RADIATOR SHOULD BE EMPTIED TO PREVENT DAMAGE.
Aluminium radiators are not suitable for district heating/heating networks. Acidity (pH) of the installation water should be between
6.5 - 7.5.
The powder-coat finish layer is not covered by the guarantee against corrosion at connections, due to improper installation or lack
of maintenance. The warranty does not cover defects caused by or resulting from improper use or installation, such as foreign
elements in the system after installation or over-tightened connections.
The finish layer of the product is not covered by the warranty when abrasive and/or chlorinated cleaning agents are used.
The warranty is void for products subjected to abnormal use and/or conditions (such as use above the specified capacity).
The guarantee does not cover leaks or corrosion at the radiator water connections due to improper installation.
x 3
x 1
x 1
x 4
x 4
x 4
x 4
x 4
x 4

LEES DIT EERST

BITTE ZUERST LESEN
ADDITIVE: Fernox Protector F1 (or equivalent)
EN