dIXEL
Connections: Screw terminal block
Power supply: from XW60K power module
Display: 3 digits, red LED, 14,2 mm high.
Power module XW60K
Case:
"OS": open board 132x 94 mm; height: 40mm.
Connections: Screw terminal block
Faston
Power supply: 230Vac
Power absorption: 10VA max.
Inputs: 2 NTC or PTC probes
Digital inputs: 1 free voltage
Relay outputs: Total current on loads MAX. 20A
compressor: relay SPST 20(8) A, 250Vac
defrost:
relay SPST 8(3) A, 250Vac
fan:
relay SPST 8(3) A, 250Vac
light:
relay SPST 8(3) A, 250Vac
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B.
Pollution grade: normal
Software class: A.
Operating temperature: 0÷60 °C.
Storage temperature: -25÷60 °C.
Relative humidity: 20
85% (no condensing)
÷
Measuring and regulation range:
NTC probe: -40÷110°C (-58÷230°F)
Resolution: 0,1 °C or 1°C or 1 °F (selectable).
Accuracy (ambient temp. 25°C): ±0,5 °C ±1 digit
14. CONNECTIONS
14.1 XW60K WIRING CONNECTIONS WITH JUMPER NOT
INSERTED
14.2 XW60K WIRING CONNECTIONS WITH JUMPER
INSERTED
MANUAL RNC 2007 053 PRELIMINARY T66 + XW60K.doc
Installing and Operating Instructions
2
2,5 mm
heat-resistant wiring and 6,3mm
≤
2
≤
2,5 mm
heat-resistant wiring and 6,3mm
15. DEFAULT SETTING VALUES
Label Name
Set Set point
Hy Differential
LS Minimum set point
US Maximum set point
Ot
Thermostat probe calibration
P2P Evaporator probe presence
OE Evaporator probe calibration
OdS Outputs delay at start up
AC Anti-short cycle delay
CCt Continuos cycle duration
Compressor ON time with faulty
COn
probe
Compressor OFF time with faulty
COF
probe
CH Kind of action
CF Temperature measurement unit
rES Resolution
dLy Display delay
Lod Probe displayed
tdF Defrost type
dtE Defrost termination temperature
IdF Interval between defrost cycles
MdF (Maximum) length for defrost
dSd Start defrost delay
dFd Displaying during defrost
dAd MAX display delay after defrost
Fdt Draining time
dPo
First defrost after startup
dAF Defrost delay after fast freezing
Fnc Fan operating mode
Fnd Fan delay after defrost
FSt Fan stop temperature
ALc Temperat. alarms configuration
ALU MAXIMUM temperature alarm
ALL Minimum temperature alarm
ALd Temperature alarm delay
Delay of temperature alarm at
dAO
start up
oA2 Relay 5-6 configuration
i1P Digital input polarity
i1F Digital input configuration
did Digital input alarm delay
Light on with door switch
Lio
activated
Number of activation of pressure
Nps
switch
Compressor status with open
odc
door:
PbC Kind of probe
dP1 Room probe display
dP2 Evaporator probe display
rEL Software release
Ptb Map code
Hidden parameters
dIXEL
Z.I. Via dell'Industria, 27 - 32010 Pieve d'Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13
http://www.dixell.com
T66 – XW60K
PRELIMINARY
Range
LS÷US
0,1÷25.5°C/ 1÷ 255°F
-50°C÷SET/-58°F÷SET
SET÷110°C/ SET ÷ 230°F
-12÷12°C /-120÷120°F
n=not present; Y=pres.
-12÷12°C /-120÷120°F
0÷255 min
0 ÷ 50 min
0.0÷24.0h
0 ÷ 255 min
0 ÷ 255 min
CL=cooling; Ht= heating
°C ÷ °F
in=integer; dE= dec.point
0 ÷ 15 min
P1;P2
EL=el. heater; in= hot gas
-50 ÷ 50 °C
1 ÷ 120 ore
0 ÷ 255 min
0÷99min
rt, it, SEt, DEF
0 ÷ 255 min
0÷120 min
n=after IdF; y=immed.
0 ÷ 23h e 50'
C-n, o-n, C-y, o-Y
0÷255min
-50÷50°C/-58÷122°F
rE= related to set;
Ab = absolute
Set÷110.0°C; Set÷230°F
-50.0°C÷Set/ -58°F÷Set
0 ÷ 255 min
0 ÷ 23h e 50'
ALr= alarm; dEF=no select it;
LHt=auxiliary; onF=always on;
Fan= no select it
oP=opening;CL=closing
EAL=extern. alarm; bAL=lock
regulation; PAL=press. switch;
dor=door switch; dEF=defrost;
LHt=disabled; Htr = Cooling -
heating
0÷255min
n, y
0 ÷15
no; Fan; CPr; F_C
Ptc; ntc
--
--
--
--
S.p.a.
E-mail:
dixell@dixell.com
Default
-5.0
2.0
-40.0
110
0.0
Y
0.0
0
1
0.0
15
30
cL
°C
dE
P1
0
EL
8
6
30
0
it
30
0
n
0.0
o-n
10
2
Ab
110
-40
15
1.3
LHt
oP
EAL
5
y
15
no
ntc
- - -
- - -
- - -
- - -
4/4