1. INTRODUCTION TO THE STARLINE ROLDECK CONTROL RDEB 2013
GB
The control is modular and can therefore be extended with the addition of separate modules if required.
The control is designed according to the "plug and play" principle. This means there is an automatic motor-
recognition between, for example, a standard motor and a pipe motor.
The control automatically selects the best control program according to the selected motor.
For the in-roller motor this means that when the Roldeck is opening, the rotational speed is automatically
limited to guarantee smooth running.
The control also recognises "plug-in modules" and activates these automatically.
The RD 2013 comes with a soft start and a soft stop.
The RD 2013 also has 4 outlets for the jetstream, filter pump, Garden lights and poollights respectively.
If the jetstream pump is in operation and the command "Roldeck close" is given, regardless of which
control is used, the jetstream pump will be switched off immediately and the Roldeck will close after a delay
of 30 seconds. The jetstream pump can only be switched on again when the Roldeck is completely open.
If the Roldeck runs in front of the injectors, for example when opening and closing, this can seriously
disrupt the functioning of the Roldeck.
During the opening or closing of the Roldeck, the control, in combination with the Starline pool control,
offers the possibility of switching off the filter pump first and activating the Roldeck after a delay of 30
seconds. As soon as the Roldeck reaches its end position (open or closed), the filter pump switches on
again automatically.
In addition the standard control has connections for the childproof safety lock, pressure measurement (only
in connection with the in-roller motor) 1 button operation.
The control is also equipped with a comprehensive error-code-diagnosis-system with which malfunctions
can be easily identified.
If the supply voltage fails all settings will remain stored in the processor, no matter how long the power
failure lasts.
Standard functions on the RD 2013
Roldeck control in combination with electronic soft start and stop
Childproof safety lock connection
Garden lights
Poollights
If desired, delayed switching on and off of filter pump
If desired, delayed switching on and off of jetstream
Temperature measure
Connection Starline electronic water-level regulator EELS 2006
The following modules can be added to the RD 2013.
Remote control. (RDRC 2013)
Automatic bottom flap control (RDAP 2013) (formerly RDAP 2006)
Electronic Brake System (RDBS 2013) brake module for in-roller motor 500 Nm
These functions are added in the form of electronic plug-in modules, which are attached to the mother print
via a connector interface.
Existing accessories, such as "remote control extension set" and the "dealer remote control", can also be