RS-232C-protocol

RS232 Setting
Minimum delay for next command: 1ms
Control Command Structure
HEX
ASCII
Operation Command
Note:
XX=00-98, projector's ID, XX=99 is for all projectors
Return Result P=Pass / F=Fail
n: 0:Disable/1: Enable/Value(0~9999)
ASCII
VXXS0001
56h Xh Xh 53h 30h 30h 30h 31h 0Dh
VXXS0002
56h Xh Xh 53h 30h 30h 30h 32h 0Dh
VXXS0003
56h Xh Xh 53h 30h 30h 30h 33h 0Dh
VXXG0004
56h Xh Xh 47h 30h 30h 30h 34h 0Dh
VXXS0005n
56h Xh Xh 53h 30h 30h 30h 35h nh 0Dh Set Air filter timer
VXXG0005
56h Xh Xh 47h 30h 30h 30h 35h 0Dh
VXXS0006
56h Xh Xh 53h 30h 30h 30h 36h 0Dh
VXXG0007
56h Xh Xh 47h 30h 30h 30h 37h 0Dh
VXXG0008
56h Xh Xh 47h 30h 30h 30h 38h 0Dh
VXXG0009
56h Xh Xh 47h 30h 30h 30h 39h 0Dh
VXXS0009n
56h Xh Xh 53h 30h 30h 30h 39h nh 0Dh Set Alter Email
Baud rate:
9600
Parity
None
check:
Data bit:
8
Stop bit:
1
Flow
None
Control
Header code
'V'
Command Group 00
HEX
DLP Beamer – Gebruikershandleiding
Command code
Command
Command
Function
Power On
Power Off
Resync
Get Lamp Hours
Get Air filter timer
System Reset
Get System Status
Get F/W Version
Get Alter EMail
51
Data code
End code
Data
0Dh
Data
CR
Description
n=0~999999
n=0~999999
0: Reset
1:Standby
2:Operation
3:Cooling
n=xxxxxx@xxxx.xxx.
xx
B
I
IJLAGE
Return Result
P/F
P/F
P/F
Pn/F
P/F
Pn/F
P/F
Pn/F
Pn/F
Pn/F
P/F