13,2V (26,4V) and the Battery Separator will connect the equipment to the battery.
Battery/ equipment / accessories protection:
All the types have a protection of the second battery and it's connected equipment of overvoltage due to a damaged voltage regulator of the alternator. If
the voltage will become too high the Battery Separator switch will open immediately and connected equipment is saved.
Installation:
If you want to use the starting contact you can connect, via a fuse, a wire to connection 85 that becomes 12V (24V) as long as you activate the starter.
Use suitable cables. Use heavy duty copper cable connectors and use wires of sufficient diameter and quality so no excess heat is produced. When using
bad material or insufficient diameter, the Battery Separator can be damaged.
ATTENTION!! Short-circuit of the plus and minus of the battery can damage your system! So make sure the connections are secure!
Primary battery 12V (24V)
Between the on/off switching is a delay to prevent the relay from switching in a short dip or rise of the battery Voltage. The relay switches off at an over
Voltage of 16V (32V) to prevent damage of the battery and equipment.
Technical specifications:
Power supply
Connection batteries
other connections
Cable suggestion
Current consumption in OFF state
Current consumption in ON state
Minimum Chargetime
Fast OFF
Connections:
30
Primary/start Battery Plus connection
85
Start contact (Only when start help used)
86
Minus. (Attention! This should always be connected). ->85 for BS140
87
Auxiliary Battery connection. If used as Voltage Dependent Switch
this is the equipment connection.
Auxiliary battery 12V (24V)
13.2V relay on (26.4V)
12.8V relay out (25.6V)
10-bits precise µProcessor
Autodetect 12/24V
M6
6,3mm faston
BS100
20mm^2
BS140
25mm^2
12V 1.5mA / 24V 1.5mA
13.5V 360mA / 27V 160mA
60 sec.
< 11.8V (12V) / <23.6V (24V) after 4 sec.
->86 for BS140
13.2V relay on (26.4V)
12.8V relay out (25.6V)